background image

Manual 

 

 

5.4 

Quick Check mode 

Simply switch on the device for entering the Quick Check Mode. You will arrive at this mode very 
quickly. 

The red and green LED will light up once a second until a spark is detected.  

When a spark is detected then the upper red LED lights up. The two lower LEDs show the 
polarity. 

Using Quick Check Mode voltage only up to 5 kV can be measured. 

 
 

Battery replacement  

 
Open the back of the hand-held device and remove the old batteries. Then put two new 3V CR2016 
Lithium batteries into the battery compartment and lock it. 
 
 

Disposal 

 
For the disposal of batteries, the 2006/66/EC

 

directive of the European Parliament applies. Due to the 

contained pollutants, batteries must not be disposed of as household waste. They must be given to 
collection points designed for that purpose. 
 
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or 
give them to a recycling company which disposes of the devices in line with law. 
 
If you have any questions, please contact PCE Instruments. 
 
 
 
 
 
 
 

 

Summary of Contents for ADD760

Page 1: ...ents UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com www pce instruments com english www pce instruments com Manual Ignition Cable Tester ADD760 Version 1 0 Date of creation 07 09 2015 Date of last change 29 09 2015 ...

Page 2: ... Device description 3 4 Technical specifications 4 5 Instructions 4 5 1 Start up operations 4 5 2 Switch on off 4 5 3 Measuring 4 5 4 Quick Check mode 5 6 Battery replacement 5 7 Disposal 5 8 Contact 6 8 1 PCE Instruments UK 6 8 2 PCE Americas 6 ...

Page 3: ...es Manual Probe extension Signal receiver 2 Safety notes Please read the manual carefully and completely before using it for the first time There is no warranty of damages or injuries caused by non observance of the manual If the device isn t in use for a long period please remove the batteries The device must be used in the described way Using the device otherwise can result in dangerous situatio...

Page 4: ... seconds Before switching off all LEDs light up and the device starts to peep 5 3 Measuring Start the engine Insert the ignition cable into the sensor For obtaining best measurement results the minimum distance of the sensor to other metal parts or cables should be 2 4cm 1 Inch You should not touch the sensor during measurement At DIS vehicles the device could detect a doubling For avoiding this e...

Page 5: ...held device and remove the old batteries Then put two new 3V CR2016 Lithium batteries into the battery compartment and lock it 7 Disposal For the disposal of batteries the 2006 66 EC directive of the European Parliament applies Due to the contained pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply wi...

Page 6: ... 13 Southpoint Business Park Ensign Way Southampton Hampshire SO31 4RF United Kingdom Phone 44 0 2380 98703 0 Fax 44 0 2380 98703 9 E mail info industrial needs com http www industrial needs com 8 2 PCE Americas PCE Americas Inc 711 Commerce Way suite 8 Jupiter Palm Beach 33458 FL USA Phone 1 561 320 9162 Fax 1 561 320 9176 E mail info pce americas com http www industrial needs com ...