Introduction 

Thank you for purchasing a PCE-313A from PCE Instruments. 
The PCE-313A humidity and temperature data logger has been designed for professional use, for 
instance in the air conditioning sector. It can measure the relative humidity as well as the ambient 
temperature. This device can be connected to K-type thermocouples. The sampling rate for real-time 
measurements can be adjusted and you can save your readings either to the internal memory of this 
instrument to an SD memory card with a capacity of 1 … 16 GB. The values saved on the SD card as an 
xls file can be transferred to a PC for further analysis. The PCE-313A can work independently, without the 
user being present during the measurement as it can be programmed via the keypad in advance. For 
long-term measurements we recommend you to use the PCE-313A with the optional mains adaptor.  

Safety notes 

Please read this manual carefully and completely before you use the device for the first time. The device 
may only be used by qualified personnel and repaired by PCE Instruments personnel. There is no 
warranty of damages or injuries caused by non-observance of the manual.

 

 
- The device may only be used within the approved temperature range. 

The case should only be opened by qualified personnel of PCE Instruments. 

 

- The instrument should never be placed with the user interface facing an object (e.g. keyboard side on a 
  table). 
- You must not make any technical changes to the device. 
- The appliance should only be cleaned with a damp cloth / use only pH-neutral cleaner, no abrasives or 
  solvents.

 

 
This manual is published by PCE Instruments without any guarantee. 
 
We expressly point to our general guarantee terms which can be found in our general terms of business. 
 
If you have any questions please contact PCE Instruments. 
 

 

Summary of Contents for PCE-313A

Page 1: ...nts UK Ltd Unit 11 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments co uk www pce instrum...

Page 2: ...information 8 5 5 6 SD memory card 8 5 6 How to transfer data to a PC 9 5 7 Settings 9 5 7 1 How to set the date and time 10 5 7 2 How to set the decimal point 10 5 7 3 Auto Power Off function 10 5 7...

Page 3: ...we recommend you to use the PCE 313A with the optional mains adaptor 2 Safety notes Please read this manual carefully and completely before you use the device for the first time The device may only b...

Page 4: ...b temperature 0 1 RH 0 1 C 0 1 C 0 1 C 0 1 C Accuracy temperature relative humidity K type 0 8 C 70 RH 3 of reading 1 RH 70 RH 3 RH 0 4 0 5 C Memory SD card 1 16 GB 2 GB included Sampling rate adjusta...

Page 5: ...t socket humidity and temperature sensor 8 K J type input 9 SD card slot 10 RS 232 output 11 Reset key 12 9 V input for mains adaptor 13 Battery compartment cover 14 Screws of the battery compartment...

Page 6: ...e device by means of the power key 2 b Insert the plug 17 of the humidity sensor into the sensor input socket 7 c Select dew point measurement by means of the Hold key 3 d You can now read the dew poi...

Page 7: ...at the SD card If you use the SD card for the first time it is necessary to format it To do so please refer to the settings chapter below c How to set the clock If you use the device for the first tim...

Page 8: ...normal measurement mode without data logger function you can check the time information via the SET key 5 which is also labelled time check You will then see the date and time in the display 5 5 5 Dat...

Page 9: ...Examples 5 7 Settings When the data logger function is deactivated press and hold the SET key 5 for more than 2 seconds This will take you to the setup menu You can navigate through the menu by pressi...

Page 10: ...y 4 5 7 4 How to set the beeper 1 When the display indicates bEEP you can select yES or no by means of the 5 and the keys 6 By selecting yES you activate the beeper which means that an acoustic signal...

Page 11: ...socket 10 The data output is a 16 bit data string which can be read out and processed in line with the users requirements See the following circuit diagram of the interface The data result in a data s...

Page 12: ...ust not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devices back We either re us...

Reviews: