background image

Manual 

 

5.6 

How to transfer data to a PC 

1. After saving data to the SD card by means of the meter, remove the SD card from its slot (9). 
2. Insert the SD memory card into the card reader of your computer. 
3. Switch on the computer and start the Windows programme Excel. You can now open the files saved on 
the SD card. Then you can process the data via Excel, e. g. create graphs. 
 
Examples: 

 

 

 

5.7 

Settings 

When the data logger function is deactivated, press and hold the SET key (5) for more than 2 seconds. 
This will take you to the setup menu. You can navigate through the menu by pressing the hold key (3): 
 

dAtE…    

set date and time (year / month / day, hour / minute / second) 

dEC…    

set decimal point format (point or comma)  

PoFF..    

Auto Power Off function on / off 

bEEP..    

set beeper (on or off)  

tYPE..    

set thermocouple (K- or J-type)  

t-

CF…    

set temperature unit (°C or °F)  

SP-

t….    

set sampling rate (hours / minutes / seconds)  

Sd F….   

format SD card 

 
You can leave the setup menu by means of the power key (2). 

Summary of Contents for PCE-313A

Page 1: ...nts UK Ltd Unit 11 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments co uk www pce instrum...

Page 2: ...information 8 5 5 6 SD memory card 8 5 6 How to transfer data to a PC 9 5 7 Settings 9 5 7 1 How to set the date and time 10 5 7 2 How to set the decimal point 10 5 7 3 Auto Power Off function 10 5 7...

Page 3: ...we recommend you to use the PCE 313A with the optional mains adaptor 2 Safety notes Please read this manual carefully and completely before you use the device for the first time The device may only b...

Page 4: ...b temperature 0 1 RH 0 1 C 0 1 C 0 1 C 0 1 C Accuracy temperature relative humidity K type 0 8 C 70 RH 3 of reading 1 RH 70 RH 3 RH 0 4 0 5 C Memory SD card 1 16 GB 2 GB included Sampling rate adjusta...

Page 5: ...t socket humidity and temperature sensor 8 K J type input 9 SD card slot 10 RS 232 output 11 Reset key 12 9 V input for mains adaptor 13 Battery compartment cover 14 Screws of the battery compartment...

Page 6: ...e device by means of the power key 2 b Insert the plug 17 of the humidity sensor into the sensor input socket 7 c Select dew point measurement by means of the Hold key 3 d You can now read the dew poi...

Page 7: ...at the SD card If you use the SD card for the first time it is necessary to format it To do so please refer to the settings chapter below c How to set the clock If you use the device for the first tim...

Page 8: ...normal measurement mode without data logger function you can check the time information via the SET key 5 which is also labelled time check You will then see the date and time in the display 5 5 5 Dat...

Page 9: ...Examples 5 7 Settings When the data logger function is deactivated press and hold the SET key 5 for more than 2 seconds This will take you to the setup menu You can navigate through the menu by pressi...

Page 10: ...y 4 5 7 4 How to set the beeper 1 When the display indicates bEEP you can select yES or no by means of the 5 and the keys 6 By selecting yES you activate the beeper which means that an acoustic signal...

Page 11: ...socket 10 The data output is a 16 bit data string which can be read out and processed in line with the users requirements See the following circuit diagram of the interface The data result in a data s...

Page 12: ...ust not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devices back We either re us...

Reviews: