background image

Manual 

 

11 

5.8 

Mains adaptor 

In addition to battery power supply, the device can also be powered by a 9 V dc mains adaptor. To do so, 
please use the 9 V input socket (12). If you use the device with the mains adaptor, it is always on. Thus, 
the power key (2) will not work. 

5.9 

System reset 

If you have an issue using the device, for example because it does not show any reaction when you press 
a key, you can reset the device to its original condition. You can do this as follows: 
When the device is on, use a pointed object to push the RESET key (11) in slightly. The device is now in 
its original condition. 

RS-232 interface 

The device is equipped with an RS-232 interface with a 3.5 mm jack socket (10). The data output is a 16 
bit data string which can be read out and processed in line with the users’ requirements. See the following 
circuit diagram of the interface: 

 

The data result in a data stream of 16 components. 

D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D0 
 

D0  

end word 

D1 & D8  

display, D1 = LSD, D8 = MSD example: when 1234 is displayed, D8 to D1 is: 
00001234  

D9  

decimal point (DP), position from right to left 0 = no DP, 1 = 1 DP, 2 = 2 DP, 3 = 3 DP  

D10  

polarity 0 = positive, 1 = negative  

D11 & D12  

displayed unit °C = 01, °F = 02, % RH = 04  

D13  

Selection of display line 1 = upper line 2 = lower line 

D14  

4  

D15  

start word 

 
RS-232 format, 9600, N8, 1 

Baud rate 

9600 

Parity 

No 

Start bit 

Stop bit 

Patents 

The following patents for the device have been granted or applied for: 

Germany  

No. 20 2008 016 337.4  

Japan  

3151214  

Taiwan  

M 358970 M 359043  

China  

ZL 2008 2 0189918.5 ZL 2008 2 0189917.0  

USA  

applied for  

 
 

 

Summary of Contents for PCE-313A

Page 1: ...nts UK Ltd Unit 11 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments co uk www pce instrum...

Page 2: ...information 8 5 5 6 SD memory card 8 5 6 How to transfer data to a PC 9 5 7 Settings 9 5 7 1 How to set the date and time 10 5 7 2 How to set the decimal point 10 5 7 3 Auto Power Off function 10 5 7...

Page 3: ...we recommend you to use the PCE 313A with the optional mains adaptor 2 Safety notes Please read this manual carefully and completely before you use the device for the first time The device may only b...

Page 4: ...b temperature 0 1 RH 0 1 C 0 1 C 0 1 C 0 1 C Accuracy temperature relative humidity K type 0 8 C 70 RH 3 of reading 1 RH 70 RH 3 RH 0 4 0 5 C Memory SD card 1 16 GB 2 GB included Sampling rate adjusta...

Page 5: ...t socket humidity and temperature sensor 8 K J type input 9 SD card slot 10 RS 232 output 11 Reset key 12 9 V input for mains adaptor 13 Battery compartment cover 14 Screws of the battery compartment...

Page 6: ...e device by means of the power key 2 b Insert the plug 17 of the humidity sensor into the sensor input socket 7 c Select dew point measurement by means of the Hold key 3 d You can now read the dew poi...

Page 7: ...at the SD card If you use the SD card for the first time it is necessary to format it To do so please refer to the settings chapter below c How to set the clock If you use the device for the first tim...

Page 8: ...normal measurement mode without data logger function you can check the time information via the SET key 5 which is also labelled time check You will then see the date and time in the display 5 5 5 Dat...

Page 9: ...Examples 5 7 Settings When the data logger function is deactivated press and hold the SET key 5 for more than 2 seconds This will take you to the setup menu You can navigate through the menu by pressi...

Page 10: ...y 4 5 7 4 How to set the beeper 1 When the display indicates bEEP you can select yES or no by means of the 5 and the keys 6 By selecting yES you activate the beeper which means that an acoustic signal...

Page 11: ...socket 10 The data output is a 16 bit data string which can be read out and processed in line with the users requirements See the following circuit diagram of the interface The data result in a data s...

Page 12: ...ust not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devices back We either re us...

Reviews: