8.4 

Setting the beeper 

1. 

When the display shows "bEEP", you can use the 

 key (3-3) and the 

 key (3-

4) to select "yES" or "no", where "yES" means that the beeper is ON and each time 
a value is stored, an acoustic signal sounds; "no" means that the beeper is OFF. 

2. 

You can confirm and save your settings with the Enter key (3-2). 

 

8.5 

Setting the decimal point 

The decimal point can be formatted as "dot" or "comma". Since in the USA the decimal 
point is a "dot" (e. g. 523.25) and in Europe the decimal point is usually a "comma" (e. g. 
523,25), the abbreviations in the display are "USA" for "dot" and "EURO" for "comma". 
 
1. 

If the display shows "dEC", you can select "USA" or "EURO" with the 

 key (3-3) 

and the 

 key (3-4). 

2. 

You can confirm and save your settings with the Enter key (3-2). 

 

8.6 

Setting the temperature unit 

1. 

If the  display shows  "t-CF", you can  use  the 

 key  (3-3)  and  the 

 key  (3-4)  to 

select  "C"  or  "F",  where  "C"  stands  for  degrees  Celsius  and  "F"  for  degrees 
Fahrenheit. 

2. 

You can confirm and save your settings with the Enter key (3-2). 

 

8.7 

Setting the RS-232 interface 

1. 

If the display shows "rS232", you can use the 

 key (3-3) and the 

 key (3-4) to 

select  "yES"  or  "no",  where  "yES"  means  that  the  RS-232  interface  (3-12)  is 
activated and "no" means that the interface (3-12) is deactivated. 

2. 

You can confirm and save your settings with the Enter key (3-2). 

 

8.8 

Setting the elevation in metres (sea level) 

For a precise CO2 measurement, it is recommended to enter the ambient elevation, also called 
"altitude above sea level".  

 

1. 

When the display shows "High", you can change the value with the 

 key (3-3) and 

the 

 key (3-4) . 

2. 

You can confirm and save your settings with the Enter key (3-2). 

 

8.9 

Setting the elevation in feet (sea level) 

For a precise CO2 measurement, it is recommended to enter the ambient elevation, also called 
"altitude above sea level".  

 

1. 

When the display shows "HighF", you can change the value with the 

-key (3-3) 

and the 

 key (3-4). 

2. 

You can confirm and save your settings with the Enter key (3-2). 

 

Power supply 

The  measuring  device  can  be  operated  with  the  9  V  DC  plug-in  mains  adaptor.  The 
connection for the external power supply is located at the bottom of the instrument (3-14). 
The  batteries  only  serve  the  purpose  of  keeping  the  internal  clock  and  the  individual 
settings. 

 

 

Summary of Contents for PCE-AQD 10

Page 1: ...O2 Data Logger User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change...

Page 2: ...ard to PC 6 8 Settings 6 8 1 SD card format 7 8 2 Setting the time 7 8 3 Setting the recording interval 7 8 4 Setting the beeper 8 8 5 Setting the decimal point 8 8 6 Setting the temperature unit 8 8...

Page 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Page 4: ...mperature Relative humidity CO2 0 50 C 10 90 RH 0 4000 ppm Resolution Temperature Relative humidity CO2 0 1 C 0 1 RH 1 ppm Accuracy Temperature Relative humidity CO2 0 8 C 4 of rdg 70 ppm 1000 ppm 5 o...

Page 5: ...pension brackets 3 8 Table stand 3 9 Battery compartment cover 3 10 Safety screw for battery compartment cover 3 11 RESET key 3 12 RS 232 output 3 13 SD card slot 3 14 9 V DC connection 3 15 CO2 senso...

Page 6: ...formatted Refer to chapter 8 1 for more information Note Please do not use an SD card formatted in another device e g digital camera In this case you have to format the SD card again in the data logge...

Page 7: ...wn the time key 3 3 for more than 2 seconds the following data appears in the display year month day hour minute second and the recording interval 6 4 SD card data structure 1 When you first insert th...

Page 8: ...e tester press the SET key 3 5 for more than 2 seconds This takes you to the setting menu and you can navigate through the menu with each further press of the SET key Sd F Format SD card dAtE Setting...

Page 9: ...Now you can move to the next value The sequence then is month day hour minute second Note The value to be set flashes 2 When you have set all the values and confirmed with the Enter key 3 2 all the s...

Page 10: ...ing the RS 232 interface 1 If the display shows rS232 you can use the key 3 3 and the key 3 4 to select yES or no where yES means that the RS 232 interface 3 12 is activated and no means that the inte...

Page 11: ...state This is done as follows While the machine is switched on press the RESET key 3 11 gently with a pointed object The machine is now reset to its original state 12 RS 232 PC interface The device h...

Page 12: ...ed pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our dev...

Page 13: ...tanbul United Kingdom SO31 4RF Italia T rkiye Tel 44 0 2380 98703 0 Telefono 39 0583 975 114 Tel 0212 471 11 47 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 Faks 0212 705 53 93 info pce instruments co uk...

Reviews: