Technical specifications 

AC current  
(50 / 60 Hz) True RMS 

Range: 200 A AC 
Accuracy: 

± 

(2.5 % + 8 dgt) 

DC current 

Range: 200 A DC 
Accuracy: ± (2,0 % + 5dgt)  

AC voltage 
(50 / 60 Hz) True RMS 

Range: 600 V AC 
Accuracy: ± (1.5 % + 8 dgt) 

DC voltage 

Range: 600 V DC 
Accuracy: ± (1.0 % + 8 dgt) 

Resistance 

Range: 

999.9 Ω 

Accuracy: ±(1,5 % + 8dgt)  

Measuring point illumination 

white LEDs 

Conductor diameter 

max. 18 mm 

Display 

3 2/3 Digit LCD with backlight  

Power Supply 

2 x 1.5 V AAA batteries 

Housing 

PVC 

Temperature range 

Operation: -

10 … +50 °C 

Storage: -

30 … +60 °C 

Air humidity range 

90 % RH (0…30 °C) 
75 % RH (30…40 °C) 
45 % RH (40…50 °C) 

Standardization 

EN61010-1; CAT II 600V  
EN61010-2-032; CAT III 300V  

Dimensions 

164 x 65 x 32 mm 

Weight 

175 g 

 

3.2 

Contents of delivery 

1 x current clamp PCE-DC2 
2 x test leads 
1 x carrying bag 
2 x batteries 
1 x instruction manual 
 

 

Summary of Contents for PCE-DC2

Page 1: ...truments UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com www pce...

Page 2: ...1 AC current measurement 5 5 2 DC current measurement 6 5 3 AC DC voltage measurement 6 5 4 Non contact voltage test 6 5 5 Resistance measuring and continuity test 6 6 Additional functions 6 6 1 Flash...

Page 3: ...observance of the manual The device may only be used in approved temperature humidity range The device should not lay face down on the workbench or work surface to avoid damage to the controls Avoid...

Page 4: ...5 8dgt Measuring point illumination white LEDs Conductor diameter max 18 mm Display 3 2 3 Digit LCD with backlight Power Supply 2 x 1 5 V AAA batteries Housing PVC Temperature range Operation 10 50 C...

Page 5: ...he old batteries and replace them with new ones After that close the battery compartment Note Only use 1 5 V AAA batteries 5 Measuring Note To avoid electric shocks be very careful when measuring curr...

Page 6: ...to the live conductor For measuring purposes it does not matter if the conductor is insulated or not If you want to detect lead fractures move the current clamp along the conductor 2 As long as the co...

Page 7: ...an also see a MAX indication If you press the button again the display shows the minimum value as well as a MIN indication Press the button once again to get to the MAX MIN mode In this mode the devic...

Page 8: ...contact PCE Instruments 7 1 PCE Instruments UK By post PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign Way Southampton Hampshire United Kingdom SO31 4RF By phone 02380 987 035 7 2 P...

Reviews: