background image

 
 

info@tursdaletechnicalservices.co.uk

 

 

 

5

1.2 Electrical Specifications 

Accuracies are specified in the way: 

±(…% of r…digits) at 23ºC±5ºC,below 80% RH. 

OHMS 

Range Resolution 

Accuracy

Max. open

Circuit Voltage 

Overload 

Protection 

40.00

 0.01

 

+(1.2%+3) 

5.8V

250Vrms 

400.0

 0.1

  

5.8V

Continuity Beeper 

Range Resolution  Operation

Resistance 

Max.open Circuit 

Voltage 

Overload

Protection 

•))) 0.01

 Resistance

35

5.8V

250Vrms

Short circuit current 

200mA

DC Voltage 

Range Resolution 

Accuracy

Input Impedance

Overload 

Protection 

1000V 1V 

+(0.8%+3)

10M

1000Vrms 

AC Voltage (40Hz~400Hz) 

Range Resolution 

Accuracy

Input Impedance

Overload 

Protection 

750V 1V 

+(1.2%+10)

10M

750Vrms 

Meg OHMS

 

Terminal 

Voltage 

Range Resolution

Accuracy

Test Current  Short circuit 

current 

125V(0%~+1

0%) 

0.125~4.000 M

0.001M

+(2%+10)

1mA 

@load125k

 

1mA

4.001~40.00 M

0.01M

+(2%+10)

40.01~400.0 M

0.1M

+(4%+5)

400.1~4000 M

1M

+(5%+5)

250V 

(0%~+10%) 

0.250~4.000 M

0.001M

+(2%+10)

1mA 

@load250k

 

1mA

4.001~40.00 M

0.01M

+(2%+10)

40.01~400.0 M

0.1M

+(3%+5)

400.1~4000 M

1M

+(4%+5)

 

500V(0%~+1

0%)  

0.500~4.000 M

0.001M

+(2%+10)

1mA 

@load500k

 

1mA

4.001~40.00 M

0.01M

+(2%+10)

40.01~400.0 M

0.1M

+(2%+5)

400.1~4000 M

1M

+(4%+5)

1000V 

(0%~+10%) 

1.000~4.000 M

0.001M

+(3%+10)

1mA 

@load1M

 

1mA

4.001~40.00 M

0.01M

+(2%+10)

40.01~400.0 M

0.1M

+(2%+5)

400.1~4000 M

1M

+(4%+5)

 

 
 
 
 

All manuals and user guides at all-guides.com

Summary of Contents for PCE-IT 100

Page 1: ...t N12B Tursdale Business Park Co Durham DH6 5PG United Kingdom Phone 44 0 191 377 3398 Fax 44 0 191 377 3357 info tursdaletechnicalservices co uk http www industrial needs com MANUAL PCE IT 100 All ma...

Page 2: ...essories 4 1 2 Electrical Specifications 5 OHMS 5 Continuity Beeper 5 DC Voltage 5 AC Voltage 40Hz 400Hz 5 Meg OHMS 5 2 PARTS CONTROLS 6 2 1 How to connect test leads 6 2 2 Battery Check UP Replacemen...

Page 3: ...ter only as specified in this manual otherwise the protection provided by the meter may be impaired z Read the operating instructions before use and follow all safety Information z Caution when workin...

Page 4: ...ay Measurement Range 4000M 125V 4000M 250V 4000M 500V 4000M 1000V 400 BZ 1000V DCV 750V ACV Sampling Rate 2 5 times per second Zero Adjustment Automatic adjustment Over Range Indicator OL of highest d...

Page 5: ...AC Voltage 40Hz 400Hz Range Resolution Accuracy Input Impedance Overload Protection 750V 1V 1 2 10 10M 750Vrms Meg OHMS Terminal Voltage Range Resolution Accuracy Test Current Short circuit current 1...

Page 6: ...AA is Required b Place back the battery cover and four the screws 2 3 Test leads check Set the range select switch to the 400 range With the tip and alligator clip of the test leads connected The indi...

Page 7: ...ltage a sting functio insulation re lation resist ZERO LIGH for 400 th rectly into th matically th ent function tance and nchronous w sistance th e is over 30 esistance t ge is over 3 on while yo y sh...

Page 8: ...a warns frequ r pushing d high voltage e secondar e insulation utomatically ONTINUI osition terminal a o both ends be switched alog bar elow approx hile the test shes along more than 3 SUREM V positio...

Page 9: ...itch If a weakness is in dicated the motor and other components should be checked individually If the motor is disconnected at the motor terminals connect one megohmmeter lead to the grounded motor ho...

Page 10: ...ision of the measurement technique http www industrial needs com measuring instruments htm NOTE This instrument doesn t have ATEX protection so it should not be used in potentially explosive atmospher...

Reviews: