Attentions 

1.  Do not disassemble the equipment without correct guide otherwise 

faults or errors may happen. 

2.    High voltage inside, be careful, only a qualified person can open it. 

3.  The optical lens is preset ready for instant use, disassembly is not 

recommended. 

4.  The machine is a sophisticated precise optical instrument, and is 

damageable, knock and impact is prohibited. 

5.    Careful operation is required to avoid damage. 

6.    Do not use the machine under humidity condition.   

7.    When the top and bottom halogen lamps are working, they may be hot, 

keep yourself/your skin and inflammable materials away from it to 

avoid scald or burn or fire.   

8.    Do not use the machine under oily fuse or dirty conditions. 

9.    Please pull out the plug when the machine is not in use. 

10. Please keep the machine in dry situation when it won’t be used within a 

long time. 

11. Please note the parameters of the power supply, do not use other brands’ 

power supply. 

 

 

 

 

 

 

 

To avoid damage during transportation, original package 

should be used to protect the sophisticated equipment, if 
lost; quality substitute package is required. 

WARNING 

The display is vulnerable and may be damaged forever should 

its interior parts are changed by any means, to avoid which please let 

a qualified person to disassemble and fix the machine when faults 

and dysfunctions happen. 

 

 

2

 

Introduction 

Consisting of motorized rotating watching device, varifocal microscope, 

CCD camera and LCD; PCE-MVM 3D is a 2/3Dimensional automatic video 

microscope. Besides, it can be connected to PC via the USB2.0 access, 

which enables the system more powerful and applicable to wider application 

range.  

Framework of the microscope system 

 

 

 

 

 

 

 

 

 

 

 

 

 

Working principles of the video microscope system 

A clear picture of tiny object could be seen through the motorized 

rotating watching device which will reflect the picture to the main optical 

lens, then, such picture would be grabbed and turned into video signal by the 

CCD camera, and then, the video signal would turn into a 3D digital picture 

on the LCD display, meanwhile, the video signal will be transformed in the 

signal transition box and then sent via the USD2.0 access to the computer for 

display, picture-grapping, photographing, measuring, saving and printing as 

Summary of Contents for PCE-MVM 3D

Page 1: ...e User Manual carefully before use 2 CONTENT Introduction 2 Framework of the microscope system 2 Working principles of the video microscope system 2 Functions and features 3 Parameters Specification 4 Instruction of whole machine 6 Operation and usage 8 Errors and dysfunctions diagnosis analysis 12 ...

Page 2: ...the sophisticated equipment if lost quality substitute package is required WARNING The display is vulnerable and may be damaged forever should its interior parts are changed by any means to avoid which please let a qualified person to disassemble and fix the machine when faults and dysfunctions happen 2 Introduction Consisting of motorized rotating watching device varifocal microscope CCD camera a...

Page 3: ...er plate easier to move the tested object 12 USB2 0 access enables the connection to computer for display picture grapping photographing measuring saving and printing etc Application Electronics Micro electronics mechanism processing medicine biology metallurgical industry material analyzing quality control analysis jewelry education and science research etc 4 Parameters Specification 1 System mag...

Page 4: ...e moving ball navigating rail Size of the plate 180X155X26mm Moving range X axis 75mm Y axis 55mm Reticle Graduation 0 1mm Connecting dia Φ95 10 Working voltage for the whole machine Power supply 100 240V AC 50 60Hz Base power supply 100 240V AC 50 60Hz 11 Physical parameters Base size 255X155X64mm L x W x H Vertical pole height 250mm Weight for whole machine approx 6kgs Notes All the abovemention...

Page 5: ...tallation a set the unit on a smooth and solid working table place the 3 wire socket in place in the rear side of the unit then plug into AC power supply outlet b set the according socket into the POWER DC 12V socket and get the unit electrified Turn on off a press button to turn on the display b press button to turn off when the unit is working Attention Please pull out the plug cut the power sup...

Page 6: ...tton on the right side of base Turn button to CW it rotates clockwide Turn button to CCW it rotates anticlockwise The switch and speed control of watching device is controlled by the button on the left side of base 5 Adjusting the brightness Adjusting brightness of the LED lamp press button OK the correspondent mark appears on the right up corner of the screen and the lamp is on direct pressing or...

Page 7: ...o white Generally results from strong lightness brightness please adjust lightness brightness to a properly extent 4 Image with white spot Generally results from refraction of the light beam from the tested object please adjust the light incidence and the lightness brightness to a properly extent Normally scattering light is a better mean of illumination 5 Malfunction of rotating watching device T...

Page 8: ... so no image appears on the screen When this happens please check the pass through which the signals are transmitted Normally the ocular microscope is deeded to be ok without outside force and if the video signal transmitting wire is ok then CCD camera will be considered to arise Attention If any dysfunction happens to CCD camera or display screen please contact the supplier for repair Please take...