129
-
sample rate
– input type:
Voltage 10 V
,
Voltage -24..24V
,
Prad -24..24mA
80 ms
– other inputs 160 ms
Output:
-
analog output - programmable, insulated galvanically,
current (0/4...20 mA, load resistance ≤ 500 Ω ) or voltage (0...10 V,
load resistance ≥ 500 Ω),
-
analog output accuracy class
0.1;
-
analog output conversion time
< 40 ms
-
relay – 1 or 2 relays; voltage free contacts, normally open,
maximum load capacity 5 A 30 V d.c. or 250 V a.c.
-
digital – RS-485 interface:
-
transmission protocol: Modbus RTU
-
transmission rate: 4800, 9600, 19200, 38400, 57600, 115200,
230400, 256000 [b/s].
-
address: 1...247
-
mode: 8N2, 8E1, 8O1, 8N1
-
maximum time to start response
200 ms
1
-
auxiliary power supply (option) 24 V d.c. / 30 mA
-
clock accuracy
1s/24 h
Power consumption
< 6 VA
Weight
< 0.25 kg
Dimensions
120 x 45 x 100 mm
Mounting
35 mm rail acc. to EN 60715
Insured protection grade by the housing
housing-side (variant incompatible with SD/SDHC cards)
IP40
housing-side (variant compatible with SD/SDHC cards)
IP30
terminals-side
IP20