98
4050
Base.Reg
w/
r
0...65535
7510
Number of polled / monitored base register
in Master / Monitor mode of RS-485 interface
4051
No.ofVal
w/
r
0...50
1
Number of polled values in Master / Monitor
mode of RS-485 interface
4052
Interw.
w/
r
1...36000
10
Polling interval in Master RS-485 mode
4053
w/
r
0...1
0
Update transmission parameters. Accepts
entered RS-485 interface settings.
4054
Language
w/
r
0...3
0
Transducer menu language:
Value
Description
0
Polish
1
English
2
German
3
French
4055
Fabr.Par
w/
r
0...1
0
Restore default settings
Value
Description
0
without changes
1
restore default settings
4056
Security
w/
r
0...9999
0
Password for changing parameters from menu
Value
Description
0
without changes
...
Entering parameter edition mode
prompts for password
4057
Time
w/
r
0...2359
-
Current time – hour, minute
This parameter uses hhmm format, where:
hh – hours, mm – minutes. Wrong hour will set
value to 23 and wrong minutes will set value
to 59. Register 4055 is cleared after writing
to register 4057
4058
w/
r
0...60
-
Current time - seconds
4059
r
0...100
-
Current time – seconds
4060
Date
w/
r
101...1231
-
Current date in format month *100 + day