background image

 

 

 

©  PCE Instruments 

 

3.8 

Continuity test 

In order to use the diode test function, follow the steps in chapter 3.6 and press the mode button 
twice  to  switch  to  the  continuity  test  function.  If  the  resistance  is  lower  than  150 

Ω  the  device 

gives out an acoustic signal. 

3.9 

Current measurement 

To use the current measurement function, connect the test lead to the device. Next, turn the tip 
of  the  device  clockwise  until  the  measuring  tip  comes  out.  Select  the  current  measurement 
function by using the function wheel. Use the mode button to select AC or DC measurement.  
Now you can perform a current measurement. 

3.10 

Non-contact voltage test 

The non-contact voltage test function can only be used on AC voltages. Use the function wheel 
to select the non-contact voltage test. Now you can hold the tip of the device against the wire to 
be  tested.  If  the  wire  is  live  the  red  LED  at  the  tip  of  the  device  will  light  up.  The  non-contact 
voltage test can be performed at a distance of 3-4 cm. 
 

 

Summary of Contents for PCE-TT 3

Page 1: ...T 3 Digital Multimeter User Manual User manuals in various languages Deutsch fran ais italiano espa ol portugu s nederlands t rk polski can be downloaded here www pce instruments com Last change 9 Aug...

Page 2: ...peration 3 3 1 Function wheel 3 3 2 Mode button 3 3 3 Range button 3 3 4 Hold button 3 3 5 Voltage measurement 3 3 6 Resistance measurement 3 3 7 Diode test 3 3 8 Continuity test 4 3 9 Current measure...

Page 3: ...be cleaned with a damp cloth Use only pH neutral cleaner no abrasives or solvents The device must only be used with accessories from PCE Instruments or equivalent Before each use inspect the case for...

Page 4: ...mA 1 5 5 digits 200 0 mA 0 1 mA AC current 50 400 Hz 20 00 mA 0 01 mA 2 0 5 digits 200 0 mA 0 1 mA Parameter Input limit mA DC mA ACV DC 200 mA DC AC V AC 600 V DC AC Resistance continuity test diode...

Page 5: ...t disappear the parameter to be measured is too high and cannot be measured with the multimeter This might cause damage to the device 3 4 Hold button By pressing the hold button you can freeze the cur...

Page 6: ...device clockwise until the measuring tip comes out Select the current measurement function by using the function wheel Use the mode button to select AC or DC measurement Now you can perform a current...

Page 7: ...pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devic...

Page 8: ...583 975 114 Fax 1 561 320 9176 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce americas com info industrial needs com info pce italia it www pce instruments com us www pce instruments com english w...

Reviews: