Safety notes 

Please read this manual carefully and completely before you use the device for the first time. The 
device  may  only  be  used  by  qualified  personnel  and  repaired  by  PCE  Instruments  personnel. 
Damage or injuries caused by non-observance of the manual are excluded from our liability and 
not covered by our warranty. 
 

 

The device must only be used as described in this instruction manual. If used otherwise, 
this can cause dangerous situations for the user and damage to the meter. 

 

The instrument may only be used if the environmental conditions (temperature, relative 
humidity, …) are within the ranges stated in the technical specifications. Do not expose 
the device to extreme temperatures, direct sunlight, extreme humidity or moisture. 

 

Do not expose the device to shocks or strong vibrations. 

 

The case should only be opened by qualified PCE Instruments personnel. 

 

Never use the instrument when your hands are wet. 

 

You must not make any technical changes to the device. 

 

The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, 
no abrasives or solvents. 

 

The device must only be used with accessories from PCE Instruments or equivalent. 

 

Before each use, inspect the case for visible damage. If any damage is visible, do not 
use the device. 

 

Do not use the instrument in explosive atmospheres. 

 

The measurement range as stated in the specifications must not be exceeded under 
any circumstances. 

 

Non-observance of the safety notes can cause damage to the device and injuries to 
the user. 

 

Never touch live components when measuring. There is danger to life. 

 

Never touch the bare measuring tips as this may result in electric shock. 

 

Before each measurement, make sure that the correct measurement range is set and 
that the test leads are connected correctly. 

 

Resistance, capacitance and temperature measurements as well as diode tests may 
only be carried out in a voltage-free state. 

 

Before replacing the batteries or the fuses, all test leads must be removed from the 
measuring instrument. 

 
We do not assume liability for printing errors or any other mistakes in this manual. 
 
We expressly point to our general guarantee terms which can be found in our general terms of 
business. 
 
If you have any questions please contact PCE Instruments. The contact details can be found at 
the end of this manual. 
 
 
 

 

Summary of Contents for PCE-TT 4

Page 1: ...gital Multimeter User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last chang...

Page 2: ...4 5 Switching on switching off 5 6 Hold function 5 7 Backlight 5 8 Toggle subfunctions 5 9 Measurement 5 9 1 Voltage measurement 5 9 2 Current measurement 6 9 3 Resistance measurement diode test cont...

Page 3: ...ral cleaner no abrasives or solvents The device must only be used with accessories from PCE Instruments or equivalent Before each use inspect the case for visible damage If any damage is visible do no...

Page 4: ...0 8 10 dgt Input resistance 10 M Maximum input voltage 1000 V DC 750 V AC RMS True RMS frequency range 45 1000 Hz Resistance 600 0 1 0 8 3 dgt 6 k 1 0 8 3 dgt 60 k 10 0 8 3 dgt 600 k 100 0 8 3 dgt 6 M...

Page 5: ...age protection 600 V AC DC Further specifications Power supply 2 x 1 5 V AA battery Operating conditions 0 40 C Storage conditions 10 50 C 75 RH Dimensions 140 x 50 x 30 mm Weight approx 119 g 4 Devic...

Page 6: ...surement 4 2 Display description Symbol Description Automatic power off is active Battery discharged Danger of electric shock AC voltage DC voltage Continuity test function Diode test function Hold fu...

Page 7: ...set your desired measuring function you can also set a sub function To do this press the SEL key until you get the desired function 9 Measurement The meter has different electronic measuring methods...

Page 8: ...with a series connection To make a frequency measurement with the current series connection now press the Hz key The current measured value is displayed directly This function is only available if th...

Page 9: ...uring larger capacitors it may take some time to charge the capacitor to determine its capacity Pay attention to the polarity when measuring After a measurement the measured capacitors are charged The...

Page 10: ...Via the V Alert key the intensity is additionally indicated on the display by means of lines Press this key again to return to normal measuring mode Note Even if no voltage is signalled voltage may st...

Page 11: ...batteries and closed the battery compartment you can use the meter again 11 Warranty You can read our warranty terms in our General Business Terms which you can find here https www pce instruments com...

Page 12: ...ce stanbul United Kingdom SO31 4RF Italia T rkiye Tel 44 0 2380 98703 0 Telefono 39 0583 975 114 Tel 0212 471 11 47 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 Faks 0212 705 53 93 info pce instruments c...

Reviews: