background image

Instructions For Use

LED 

Videoscope

 PCE-VE 700

Visualization system for industrial endoscopy

PCE Americas Inc.

711 Commerce Way 

Suite 8 

Jupiter

FL-33458

USA

From outside US: +1

Tel: (561) 320-9162

Fax: (561) 320-9176

info@pce-americas.com

www.pce-instruments.com/english

www.pce-instruments.com

PCE Instruments UK Ltd.

Units 12/13 

Southpoint Business Park 

Ensign way

Hampshire / Southampton

United Kingdom, SO31 4RF

From outside UK: +44

Tel: (0) 2380 98703 0

Fax: (0) 2380 98703 9

info@industrial-needs.com

Summary of Contents for PCE-VE 700

Page 1: ...FL 33458 USA From outside US 1 Tel 561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Business Pa...

Page 2: ...Instructions For Use LED BORESCOPE PCE VE 700 17 Feb 2016 Version 0 Page 2 of 28 TPA500 PCE 00 Version 0 2016 Feb 17...

Page 3: ...mation on the Nameplate 11 1 6 Service Department Contact Details 11 2 Use 12 2 1 Handling Endoscopic Probes 12 2 2 Installation and Connecting the Power Supply 12 2 3 Connection of a Monitor 13 2 4 C...

Page 4: ...016 Version 0 Page 4 of 28 5 Product Data 24 5 1 Technical Data 24 5 1 1 Controller 24 5 1 2 Camera Head 24 5 2 Ambient Conditions 25 5 2 1 Transport and Storage Conditions 25 5 2 2 Operating Conditio...

Page 5: ...700 These instructions for use are an integral component of the device and contain all the information required by users and operators for safe and proper use 0 2 Target Group These instructions for u...

Page 6: ...are developed and manufactured to the highest quality standards Risks despite the high quality Although this device corresponds to the current state of the art risks could still arise during initial o...

Page 7: ...mi flexible and flexible endoscope probes is available in different lengths and diameters for the camera system The brightness of the durable and maintenance free LED can be continuously ad justed The...

Page 8: ...PCE VE 700 17 Feb 2016 Version 0 Page 8 of 28 1 4 2 Visual Overview Camera Head Figure 1 1 Camera head 1 Camera head 2 Focusing 3 Controller CCU connection cable 4 LED light source 5 FlexiLock Lock fo...

Page 9: ...r Use LED BORESCOPE PCE VE 700 17 Feb 2016 Version 0 Page 9 of 28 Controller Front View Figure 1 2 Front view of the controller 10 ON OFF switch 11 Window function 12 Gain control 13 White balance 14...

Page 10: ...Use LED BORESCOPE PCE VE 700 17 Feb 2016 Version 0 Page 10 of 28 Controller Rear View Figure 1 3 Rear View of the Controller 16 Power supply connection 12 V DC 17 Service interface 18 Video output S...

Page 11: ...heric pressure during storage 1 5 2 Information on the Nameplate This section describes the different pictograms found on the nameplate located on the underside of the device Adhere to the instruction...

Page 12: ...reless movements particularly if the probe undergoes some kind of im pact either when it is being inserted or being tilted when it is being with drawn Damaged probes can be repaired in many cases In o...

Page 13: ...onitor that is being used does not support S Video use the composite output and the composite cable that came with the controller Note The S video connection provides the best image quality 2 If neces...

Page 14: ...of an Endoscopic Probe Connecting endoscopic probes Select the endoscope probe in accordance with the object to be examined Proceed as follows 1 Open the lock on the camera head and remove the protect...

Page 15: ...nitor varies depending on the probe that is used Optimize the picture display by selecting the appropriate window size Proceed as follows 1 Press the Windows button on the front of the controller A wi...

Page 16: ...alance OK appears on the screen Completed 2 11 Setting of the Light Amplification on the Screen Setting the light amplification Adapt the screen image to a dark environment by intensifying the monitor...

Page 17: ...con nected to on and launch the documentation software Setting window sizes 3 Set the window size when you see the endoscopic image on the monitor see section 2 8 Focus the image 4 Bring the endoscop...

Page 18: ...n or isopropyl alcohol Stubborn stains can be removed with a mild ammonia based detergent Do not use abrasives or solvents since such agents may damage the paint and the labeling on the front panel 3...

Page 19: ...press the tip of the probe against or past any immovable object Proceed as follows 1 Clean the probe with a soft cloth that has been slightly moistened with a cleaning solution Do not use any metal br...

Page 20: ...the power cord NOTICE Pulling the power cable will damage it Disconnect the power at the plug 2 Detach the fuse holder with a counterclockwise quarter turn Use a screwdriv er or a coin 3 Carefully rem...

Page 21: ...ly see Use chapter Connection cable not connected or defective Connect the camera head to the controller Check the plug for moisture If the cable is defec tive send it in for repair Monitor not tuned...

Page 22: ...ns For Use LED BORESCOPE PCE VE 700 17 Feb 2016 Version 0 Page 22 of 28 Issue Possible Causes Fixes Check the mains connection and connect the power if necessary No operation No power supply Check the...

Page 23: ...ease contact one of our branch offices Contact details can be found on the back of these instructions When you send in equipment please enclose as accurate a fault description as you can and note down...

Page 24: ...ply GlobTek Inc GTM21089 1512 T3 Input Power supply 100 240 V AC 50 60 Hz max 0 5 A Output 12 V DC max 1 25 A Fuse T 800 250 V 5 x 20 mm Brightness control automatic Signal noise ratio SNR 46 dB S Vid...

Page 25: ...is best stored either separately or in a carrying case To avoid damage keep out of direct sunlight and away from high temperatures high humidity and radiation Temperature 0 C to 50 C Relative humidit...

Page 26: ...g the device and its components you must adhere to the applicable national regulations governing waste disposal and recycling Any product carrying this symbol must be disposed of separately through de...

Page 27: ......

Page 28: ...PCE Deutschland GmbH Im Langel 4 59872 Meschede Germany Telefon 49 0 2903 976 99 0 Fax 49 0 2903 976 99 29 E Mail info pce instruments com...

Reviews: