GRL-PCIE5-CEM-RXA User Guide and MOI
Rev7.0
© Granite River Labs 2022 Version 7.0, June 2022. Updated 06.29.2022
Page 105 of 123
9.3.4
Voltage Setup Steps of AH54192A-01
1.
Remove the dedicated DC power cable with the AH54192A.
2.
While checking the voltage monitor, switch between V
CC
/V
amp
/V
BT
with the voltage selector and
adjust each to the typ. value.
3.
Turn off the power and connect the dedicated DC power cable to the AH54192A.
V
BT
adjustment knob
Voltage monitor
Current monitor
Voltage selector
V
amp
adjustment knob
V
CC
adjustment knob