NEXUS
Generator & Multi-head Inflator user manual
www.pclairtechnology.com
Problem
Possible Cause
Solution
No display
No power connected
Switch power on
No inflation process
Tyre is below 3 psi
Faulty connector
Press flat tyre button
Replace faulty connector
Buzzer does not sound
Buzzer volume has been turned off
Buzzer is damaged
Turn buzzer on
Replace buzzer
Inflation process starts but does
not complete
Low or no supply pressure
Leaks exist
Check supply pressure
Confirm leaks do not exist
Supply pressure leaks out input Input and tyre hoses are incorrectly reversed
Ensure input connection is to offset port, tyre
connection is central between input and exhaust
Inflating or deflating is very slow Check that mesh filters under input and output
port fittings are blocked
Clean and or replace mesh filters
Connector will not seal to the
tyre stems
Connector worn
Replace connector
Connector leak while not
connected to tyres
Connector worn
Replace connector
E1
Unstable or insufficient supply pressure
Check the supply pressure
E4
Small volume, caused inflator to check pressure
> 2bar / 29psi over target pressure
Check hose is not kinked or blocked, ensure a OPEN
END connector is installed
E5
Inflator started under pressure i.e. is connected
to tyre or a CLOSED END connector is being used
Remove hose from tyre and allow inflator to reset
Change connector to OPEN END type
E6
Pressure sensor drift out
New sensor required - Refer to authorised repairer
E8
Pressure sensor disconnected from PCB or faulty New sensor required - Refer to authorised repairer
E9
Pressure sensor failure - high
New sensor required - Refer to authorised repairer
E10
Under voltage
Check power supply
E11
Over voltage
Check power supply - Refer to authorised repairer
E12
Checksum corrupted
New PCB required - Refer to authorised repairer
E13
Lost or corrupted calibration settings
New PCB required - Refer to authorised repairer
E14
Count issue
New PCB required - Refer to authorised repairer
E17
Calibration settings corrupt
Recalibrate unit - Refer to authorised repairer
E18
Runtime error
New PCB required - Refer to authorised repairer
E19
Touch screen error
New PCB required - Refer to authorised repairer
E20 - E23
Start-up sequence error(s)
New PCB required - Refer to authorised repairer
E24
PSA count/run hours error
New PCB required - Refer to authorised repairer
E25
N2 count/run hours error
New PCB required - Refer to authorised repairer
E26
Tank sensor under range
New sensor required - Refer to authorised repairer
E27
Tank sensor over range
New sensor required - Refer to authorised repairer
E28
Signature mismatch / PCB error
New PCB required - Refer to authorised repairer
E35
Communications failure
Switch machine off and back on - if error still
persists please refer to authorised repairer.
Trouble Shooting Guide/Error Messages