background image

NEXUS 

Generator & Multi-head Inflator user manual

 

www.pclairtechnology.com 

PCL LIMITED WARRANTY 

 
PCL warrants the components of each unit

 

to which this Limited Warranty applies against defects in materials and workmanship for 

a period of twelve (12) months from date of sale (as evidenced by bill of sale or equivalent) or for a period of eighteen (18) months 
from date of shipment from PCL manufacturing facility (identifiable by the serial number and noted on original bill of lading from 
the manufacturing facility), whichever period is shorter. During this warranty period and subject to the conditions set forth in this 
statement, PCL will, at its option, repair or replace component parts that were defective at the time of shipment from PCL 
manufacturing facility, subject, however, to the following specific EXCLUSIONS: hoses and connections. 
 
Repair or replacement will not extend the warranty period. 
 
Customer must give PCL timely notice of any warranty claim by contacting an authorized PCL service centre. Claims must be 
accompanied by (1) evidence, by a bill of sale or equivalent, which clearly establishes date of purchase of the unit and (2) the 
serial number, found on the unit. Customers must properly pack parts in their original or equivalent packaging, prepay shipping 
charges, and insure the shipment or accept the risk for loss or damage in shipment. Return shipment to customer will be freight 
collect unless otherwise agreed. For service at a customers location, customer will be charged the then prevailing service rates . 
 
The Limited Warranty applies to PCL manufactured units

 

only. Items listed in the applicable operators manual under routine 

maintenance are not covered by this or any other warranty. Failure to complete maintenance as stated in any applicable 
maintenance schedule will void the Limited Warranty. The Limited Warranty is expressly conditioned upon proper and normal use 
and service of the unit and upon strict compliance by customer with all of PCL instructions and recommendations for installation, 
operation and maintenance. The Limited Warranty does not apply to the unit or parts that are damaged or become defective due to 
improper handling, maintenance, storage, use, or operation, and does not cover ordinary wear and tear, corrosion, or erosion. 
 

THE LIMITED WARRANTY SET FORTH IN THIS STATEMENT CONSTITUTES PCL'S SOLE WARRANTY FOR THE UNIT AND 
THE REMEDIES SET FORTH HEREIN CONSTITUTE CUSTOMERS SOLE REMEDIES FOR BREACH OF WARRANTY. THIS 
LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, IN FACT OR BY LAW, 
INCLUDING WITHOUT LIMITING THE GENERALITY OF THE FOREGOING, ANY WARRANTY OR MERCHANTABILITY OR 
FITNESS FOR A PARTICULAR PURPOSE. 

 
Determination of the suitability of the unit

 

for the use contemplated by the customer is the sole responsibility of the customer. PCL 

shall not, under any circumstances, be liable in contract, tort or otherwise (including negligence and strict liability) for indirect, 
special, incidental, or consequential damages, and PCL's total liability shall not exceed the net purchase price for the unit. PCL shall 
be excused for delay or inability to perform obligations due to events beyond its reasonable control. 

CUT HERE 

Mail to: 

Warranty Department 
PCL 
Holbrook Rise 
Holbrook Industrial Estate 
Sheffield 
S20 3GE 
United Kingdom 

Warranty Registration 

Please complete and mail this form to activate warranty 

Or visit us at www.pclairtechnology.com 

 
Name  ________________________________________ Title  _________   
 
Company Name  ______________________________________________   
 
Type of Business   _____________________________________________   
 
Address   ____________________________________________________   
 
City  _______________ County  _______________ Post Code  __________   
 
Telephone  ___________________________________________________   
 
Part Number  ____________________ Serial No  ____________________   
 
Purchased From  ______________________________________________   
 
Purchase Date   _________________________   

Summary of Contents for NEX2/MQ

Page 1: ...is instruction manual to all users The employer must also ensure all users read understand and follow the instructions as described in the manual safety warnings labels etc Please read and save these...

Page 2: ...ximum permissible error MPE 0 08 bar Each unit before release is checked and calibrated on test equipment that has accuracy traceable to a UKAS Laboratory No 0221 referenced to certificate 0029346 NEX...

Page 3: ...screws and washers provided fig2 The two slotted bracket mounts are already pre attached to the filter fig3 3 Attachment of pneumatic pipe to the filtration unit Pipe A is attached to the right hand s...

Page 4: ...to the adaptor Please note the N6 version has a combination filter unit 2 Connect the mains power lead to the IEC socket at the back of the unit cabinet as shown in FIG 8 3 Turn on off switch to the o...

Page 5: ...3 Connect the hoses marked with Blue indicator to the front two tyres and connect the hoses marked with white indicator to the rear two tyres 4 Auto deflation will commence with the default 2 purging...

Page 6: ...d 5 cycles increase cycles to improve N2 tyre purity On N6 models ONLY when the desired inflation pressure is above 60psi 4 1bar you only require 1 purge as standard to achieve an acceptable purity le...

Page 7: ...your region or country The unit is designed and built to the relevant basic health and safety requirements of the EC This product can be dangerous if used improperly Children should not be allowed to...

Page 8: ...om Filter regulator unit LCD Display Valve cap tray Hose hooks Output hose connections 4 individual exhausts 90mm castors Rear tyres control panel On Off switch Auxiliary port N2 Tank pressure Nitroge...

Page 9: ...Test Port This is located on the side of the unit below the Nitrogen Pressure Gauge and is designed to identify the purity of Nitrogen being produced by the machine To identify the purity of Nitrogen...

Page 10: ...move hose from tyre and allow inflator to reset Change connector to OPEN END type E6 Pressure sensor drift out New sensor required Refer to authorised repairer E8 Pressure sensor disconnected from PCB...

Page 11: ...d normal use and service of the unit and upon strict compliance by customer with all of PCL instructions and recommendations for installation operation and maintenance The Limited Warranty does not ap...

Page 12: ...2004 108 EC EMC directive confirmed by report No 10655 TR 1 73 23 EEC LOW Voltage Directive as amended by 93 68 EEC Emission EN 61000 6 3 2007 Electromagnetic compatibility Generic standards EN 55016...

Page 13: ...r die Anweisungen der Bedienungsanleitung die Etiketten Warnhinweise usw lesen verstehen und befolgen Bitte lesen Sie diese Bedienungsanleitung und bewahren Sie sie auf Lesen Sie die Anleitung sorgf l...

Page 14: ...n Betrieb mit der installierten Erdleitung ausgelegt Gem Klasse 1 Basisisolierung in Verbindung mit Schutzerdung Kalibrierung und Genauigkeit Die Genauigkeit unserer digitalen Ger te bei Freigabe ab W...

Page 15: ...n mitgelieferten Schrauben und Unterlegscheiben Abb 2 Die beiden Halterungen mit Schlitz sind bereits am Filter vorbefestigt Abb 3 3 Befestigung der Druckluftleitung an der Filtereinheit Leitung A wir...

Page 16: ...Beachten Sie bitte dass die N6 Version eine Kombi Filtereinheit hat 2 Schlie en Sie das Netzkabel an die IEC Buchse auf der R ckseite des Ger tegeh uses an wie in Abb 8 gezeigt 3 Schalten Sie den Ein...

Page 17: ...markierten Schlauch an den passenden Reifen anschlie en Blau markierte Schl uche f r die Vorderreifen Wei markierte Schl uche f r die Hinterreifen Automatisches Ablassen der Luft mit den zwei Ablassz...

Page 18: ...Dr cken der Tasten oder lassen sich diese Parameter anzeigen Die drei Parameter sind unter 1 Parameter genau beschrieben 3 Um einen der Parameter aufzurufen dr cken Sie auf Start dies ffnet die Inhal...

Page 19: ...t wurde entsprechend den grundlegenden Gesundheits und Sicherheitsanforderungen der EU entworfen und gebaut Dieses Produkt kann bei unsachgem er Verwendung gef hrlich sein Kinder d rfen dieses Ger t...

Page 20: ...lterregler Einheit Ventilkappenmulde Schlauchhaken 4 individuelle Auslass ffnungen 90 mm Rollen Ein Ausschalter Hilfsanschluss N2 Tankdruck Kontrollpunkt f r Reinheit des Stickstoffs Griffe Ger teansi...

Page 21: ...er teseite unter dem Stickstoff Druckmessger t und dient der Messung der Reinheit des von der Maschine erzeugten Stickstoffs Entfernen Sie zur Messung der Reinheit des produzierten Stickstoffs einfach...

Page 22: ...llger t zur cksetzen Ersetzen Sie das Verbindungsst ck durch ein Verbindungsst ck mit OFFENEM ENDE E6 Drucksensor weicht ab Neuer Sensor erforderlich Wenden Sie sich an eine befugte Reparaturstelle E8...

Page 23: ...nd Empfehlungen von PCL zur Installation zum Betrieb und zur Wartung durch den Kunden abh ngig Die beschr nkte Garantie gilt nicht f r Ger te oder Teile die durch unsachgem en Umgang Wartung Lagerung...

Page 24: ...mungen der folgenden EG Richtlinien 2004 108 EG EMV Richtlinie best tigt von Bericht Nr 10655 TR 1 73 23 EEG Niederspannungsrichtlinie ge ndert durch 93 68 EEG Emission EN 61000 6 3 2007 EMV Fachgrund...

Reviews: