NEXUS
Generator Only user manual
www.pclairtechnology.com
General Specifications
N6 Version
Fig 7
Fig 10
System set-up instructions
Before installing ANY of the below elements
you MUST ensure the output port towards
the bottom of the unit has been connected
using a Rp 1/4 fitting (1/4 NPT for US versions) from an air hose
which terminates in a coupling connection. This will prevent the
unit from exhausting the pressure coming from the receiver tank
from this port.
1. Connect to air supply using Rp 1/4 (1/4 NPT for US versions)
fitting into the compressed air inlet port. See Fig. 8. Please note
the N6 version has a combination filter unit.
2. Connect the mains power lead to the IEC socket at the back of
the unit cabinet as shown in FIG 9 and plug into your normal air
supply using the socket provided.
3. Turn on/off switch to the ‘on’ position shown in FIG 10.
Fig 7
Output port
N6 Version
Fig 8
Fig 9
4. The digital tank contents gauge on the front of the unit will then
fill automatically until it has reached the tank set shut off pressure.
This is factory set to 8bar/116psi as standard.
5. Once the tank set pressure is reached (8bar) and the unit has
stopped filtering it is ready to use via your existing handheld or
fixed inflation device.
8
BAR
N2
N2 flashes on the screen
The end pressure