30
Bonding lug
In.xe.ce electrical specifications:
Input rating: 230 V
~
nominal
(Single phase input Only; multi-phase not supported)
32 A absolute maximum, 50 Hz nominal.
Correct wiring of the electrical service
box, RCD protection device, and pack
terminal block is essential!
Contact qualified, licensed electrician.
In.XE Platform Control Center
1 x 230 V~ (1 x 32A) single phase,
or
1 x 230 V~ (2 x 16A) dual phase
Wiring Installation—EXPORT GUIDELINES in.xe ce
All installations and connections are to be performed by a qualified, licensed electrician only and in accord-
ance with local regulations. Identify the correct CE platform on the spa unit, in accordance with the home’s
electrical output, and follow the guidelines below. Ensure power is turned off prior to making any electri-
cal connections.
This product must always be connected to a circuit protected by a residual-current device (RCD) having
a rated operating residual-current not exceeding 30 mA. Proper wiring of the electrical service box, RCD
and in.xe.ce terminal block is essential! Check your electrical code for local regulations. Only copper
wire should be used, never aluminum.
!
Warning!
INSTALLATION GUIDELINES for IN.XE CE
SE series standard platform, 500
series control