Water Maintenance and Care
78
Water Care Schedule
Before Use:
Each time before the unit is used, check the water with a test strip for proper sanitation levels and adjust accordingly
achieving the optimum 2-4 ppm level. The unit should not be used if the level is 5 ppm or higher.
Every Other Day:
Using test strips, monitor the pH, alkalinity and sanitizer levels. The pH should read between 7.4-7.6, alkalinity
between 100-120 ppm.
Weekly:
Add non-chlorine shock as needed to maintain correct level dependent upon amount of users, frequency and length of
use during that week.
Monthly:
Change the cartridge filter. Soak overnight in a non-sudsing cleanser, preferably Filter Clean available at your retailer.
Rinse well and replace. Be sure to turn off all circulation for removal and replacement. Review in Maintenance section.
Every 6 Months:
Drain and refill your unit. Wipe down the acrylic surface, install a clean filter. Refer to the Maintenance
section.
Troubleshooting Reference
Symptom
Probable Cause
Suggested Correction
Cloudy Water
Colored Water
Foaming
Skin/Eye Irritation
Stains at Waterline,
Pillows, etc.
pH Fluctuation
pH Resistance
Sanitizer Inefficiency
Scale Formation
Algae Formation
Corrosion in Fittings and
Components
High total alkalinity levels, High pH
levels, High calcium hardness. Algae
growth, low sanitizer levels, high user
load, pets, rain. Overuse of defoamer.
Red-Brown; overall imbalance
Blue-Green; high pH level.
Low calcium hardness. Build up of
soaps, lotions, organic matter, etc.
pH level imbalance. Low sanitizer level.
Low alkalinity, pH levels.
Low alkalinity levels.
High alkalinity levels.
High pH and/or alkalinity level.
High pH, calcium harness and/or
alkalinity levels.
Low sanitizer level.
Low pH and/or alkalinity levels. High
chlorine level.
Test levels and make correcting adjustments.
Brown-Red; Test pH, alkalinity and calcium
hardness. Drain and refill if necessary.
Blue-Green; Test pH and make adjustments.
Raise calcium hardness level. Use defoaming
agent. Replace filter. Drain if necessary.
Test pH, alkalinity and sanitizer levels. Make
adjustments. Shock if necessary.
Adjust pH and alkalinity. Drain, clean off
stained areas, change filter and refill.
Test alkalinity level and make adjustments.
Test alkalinity level and make adjustments.
Test both levels and make adjustments.
Test all levels and make adjustments. Drain
and refill if necessary.
Clean spa walls, add algaecide*, add shock.
Test all levels and make adjustments. (This
build-up may cause operation failure and void
warranty.)
*
Avoid using any biguanide or copper based algaecide in the unit. Use of these products is not recommended and may void the warranty
Summary of Contents for Summit SX15
Page 2: ......
Page 75: ...Operation Systems WAVE Wireless Control option 72...