7
AC Current
(Autoranging for
A and mA)
Range
Resolution
Accuracy
600.0
A
0.1
A
± 1.5% of rdg ± 5 dgts
6000
A
1
A
± 1.8% of rdg ± 5 dgts
60.00mA
10
A
600.0mA
100
A
10A
10mA
± 3.0% of rdg ± 7 dgts
Overload Protection: 0.8A / 250V and 10A / 250V Fuse.
Frequency Range: 50 to 400 Hz
Maximum Input: 600mA DC or 600mA AC RMS on
A / mA
ranges, 10A DC or AC RMS on 10A range.
Resistance
(Autoranging)
Range
Resolution
Accuracy
6
0.1Ω
± 1.2% of rdg ± 4 dgts
6
1
Ω
± 1.0% of rdg ± 2 dgts
6
10
Ω
± 1.5% of rdg ± 2 dgts
6
100
Ω
6
1k
Ω
6
10k
Ω
± 2.0% of rdg ± 3 dgts
Input Protection: 250V DC or 250V AC RMS.
Capacitance
(Autoranging)
Range
Resolution
Accuracy
40.00nF
10pF
± 5.0% of rdg ±20dgts
400.0nF
0.1nF
± 3.0% of rdg ± 5 dgts
4.000
F
1nF
40.00
F
10nF
400.0
F
0.1
F
± 5.0% of rdg ± 5 dgts
1000.0
F*
1
F
± 10.0% of rdg ± 5 dgts