Safety Cont’d

 

IMPORTANT

 

  To maintain accuracy of the meter, replace the exhausted  battery 

immediately when the battery symbol “      “  appears on the meter 
display. 

 

  Avoid measuring error from outside interference.  Keep the meter 

away from spark plugs or coil wires. 

 

  Avoid damaging the meter when testing voltage.    Disconnect the test 

leads from the test points before changing functions. 

 

  Do not exceed the limits shown in the table below: 

 
 
 

Function 
 

Terminal 

Input limit 

DC/AC Volts, 
Ohm/Continuity 
/Diode,CAP. 
Adaptor, Type-K 
TEMP.,Hz,%Duty, 
mS Dwell, RPM 

 

V-

Ω

-RPM 

 

600Volts AC/ DC 

AC/DC 

μ

A mA 

μ

A / mA 

400mA DC/AC 

AC/DC20A 

20A 

*20A DC/AC 

 
*20 Amp measurement for 30 seconds maximum. 

 

 

 

 

 

 

 

 

Getting Started 

 

This chapter will help you get started. It describes the basic functions of 
the Meter. 
 

Meter Basics   

1. Digital LCD display 

  Display features: 

1a. Symbols to identify function 

1b. Four character digital display 

 

The digital display  is best for stable 

input. The bar graph is best for rapidly 

changing input. 

 

2. Function buttons 

Press the button to select a function. A 

symbol will display to verify your 

choice. 

 

3. Rotary Function Dial 

Turn this switch to select a function or 

turn the meter OFF. 

 

4. Volts Terminal 

The Red test lead is used to measure Amps, Volts, Ohms, TEMP, Hz, 

RPM, Cap, mS and Dwell.   

The Black test lead is used in the Common (COM) terminal for all tests 

and measurements. 

¦ ¸

Auto Power Off

4

2

1a

1b

2

3

4

Summary of Contents for DM-930

Page 1: ...1 0 DM 930 AUTOMOTIVE MULTIMETER INSTRUCTION MANUAL Auto Power Off 4 2...

Page 2: ...t tested must be protected by a 20A fuse or circuit breaker Do not use the meter if it has been damaged Do not use any test leads if the insulation is damaged or if metal is exposed Safety Cont d Dang...

Page 3: ...C AC DC20A 20A 20A DC AC 20 Amp measurement for 30 seconds maximum Getting Started This chapter will help you get started It describes the basic functions of the Meter Meter Basics 1 Digital LCD displ...

Page 4: ...DIS Hz ms CYL Button Press to this button to select STROKE 4 2DIS Hz ms CYL range V A Resistance manual Range Manual Ranging The meter turns on in the autoranging mode Press the Range button to go to...

Page 5: ...Pmin or Pmax indicator switches off Note If the Function switch position is changed after a calibration the Peak Hold calibration must be repeated for the new function selected MAX MIN 1 Press the MA...

Page 6: ...cation that has capacitors in the circuit be sure to turn the power OFF on the test circuit and discharge all capacitors Accurate measurement is not possible if external or residual voltage is present...

Page 7: ...re performing any work Select the Capacitance CAP function with the function dial and MODE button Insert Black lead in COM terminal Red lead in V RPM terminal CAUTION When checking in circuit capacita...

Page 8: ...nsure of the current draw IMPORTANT Turn OFF all power to the circuit or disconnect the circuit from the power source Connect The Red probe to the side of the circuit closest to the power source The B...

Page 9: ...in COM terminal Red lead in V RPM terminal Connect the Black test probe to ground Connect the Red test probe to the signal wire circuit The illustration for a mixture control solenoid is shown with th...

Page 10: ...ct black test probe to a good ground at the fuel injector or the negative vehicle battery post Connect red test probe to the fuel injector solenoid driver input on the jumper cable Start the engine A...

Page 11: ...w battery indication The is displayed when the battery voltage drops below the operating level Measurement rate 2 times per second nominal Auto power off Meter automatically shuts down after approx 30...

Page 12: ...Resistance Range Resolution Accuracy 400 0 0 1 1 2 of rdg 4 dgts 4 000k 1 1 0 of rdg 2 dgts 40 00k 10 1 2 of rdg 2 dgts 400 0k 100 4 000M 1k 40 00M 10k 2 0 of rdg 3 dgts Capacitance Range Resoluti on...

Page 13: ...t leads from the meter 2 Open the battery door by loosening the screw using a Phillips head screwdriver 3 Insert the battery into battery holder observing the correct polarity 4 Put the battery door b...

Page 14: ...still toggled ON Warranty This PDI product is warrantied to be free from defects in materials and workmanship for a period of two 2 years from the verified date of purchase During this warranty period...

Reviews: