INSTALLATION & SAFETY INSTRUCTIONS
PDI Communication Systems, Inc. 40 Greenwood Lane Springboro, Ohio 45066 USA PH +1-937-743-6010 FX +1 -937-743-5664
PD 196-011 Rev 3
TV DEAD
•
The TV is powered using an external power supply. Verify 28 VAC is being supplied on the coax.
•
Power is OFF, check fuse or circuit breaker on external power supply.
•
Coax is not connected. Check all coax connection including those in the nose and base of support arm.
TV SHUTS OFF
•
Wrong Cable. Due to long cable runs encountered in hospital installations, coaxial cable employing a solid copper center
conductor and copper shield is required. Cable run lengths MUST NOT exceed 150 feet. Required coaxial cable numbers
include Alpha 9804C (non-plenum), Belden 9248 (non-plenum), West Penn 806 (non-plenum), or West Penn 25806 (plenum),
which have been tested with coax line-powered televisions. USE OF ANY OTHER CABLE NUMBER IS NOT RECOMMENDED.
•
Sleep Timer is set.
•
Power interrupted.
POOR RECEPTION
•
Station or CATV experiencing problems, tune to another station.
•
Make sure channels are set into memory.
•
Check CATV connections.
•
Check for sources of possible interference.
NO RECEPTION
•
Check all CATV cable connections.
•
Set TV/CATV menu option to CATV mode.
NO RECEPTION ABOVE CHANNEL 13
•
Make sure TV/CATV menu option is in the appropriate mode.
TROUBLESHOOTING
PDI-405C-22 PILF Support Arm
PDI-178CP Wall Bracket
PDI-771CA Individual
Wall Bracket Power Supply
PD108-206-13B