READ
AND
FOLLOW
ALL
INSTRUCTIONS!!
This
unit
is
a
professional
‐
grade
product.
A
knowledge
of
construc on
techniques,
plumbing
and
electrical
installa on
according
to
codes
are
required
for
proper
installa on
and
user
sa sfac on.
It
is
recommended
that
a
licensed
contractor
perform
the
installa on.
Warranty
is
voided
for
improper
Installa on
related
issues.
It
is
the
responsibility
of
the
home
owner
to
ensure
that
all
users
of
the
swim
spa
are
adequately
informed
of
all
precau ons.
Use
the
swim
spa
only
as
described
in
this
manual.
The
swim
spa
is
intended
for
home
use
only.
Do
not
use
the
swim
spa
in
a
commercial
or
rental
se ng.
All
warran es
will
be
voided.
GROUND
ALL
METAL
ELECTRICAL
EQUIPMENT
A
green
colored
terminal
or
a
terminal
marked
G,
GR,
Ground,
or
Grounding,
is
located
inside
the
supply
terminal
box
or
compartment.
This
terminal
must
be
connected
to
the
grounding
means
provided
in
the
electric
supply
service
panel,
using
a
con nuous
copper
wire
equivalent
in
size
to
the
circuit
conductors
supplying
this
equipment.
*
according
to,
but
not
limited
to:
NEC,
NFPA
70,
Sec on
680.40,
UL
1563.
At
least
two
lugs
marked
“Bonding
Lugs”
are
provided
on
the
external
surface
or
on
the
inside
of
the
supply
terminal
box
or
compartment.
Connect
the
local
common
bonding
grid
(household
ground)
in
the
area
of
the
swim
spa
to
these
terminals,
using
an
insulated
or
bare
copper
conductor
not
smaller
than
No.
6
AWG.
All
fi
eld
‐
installed
metal
components
such
as
rails,
ladders,
drains
or
similar
hardware
located
within
5
feet
of
the
swim
spa
or
hot
tub
must
be
bonded
to
the
equipment
grounding
bus
with
copper
conductors
not
smaller
than
No.
6
AWG.
All
metal
surfaces
within
5
feet
of
the
swim
spa
must
be
bonded
to
the
home
bonding
grid.
GROUND
FAULT
CIRCUIT
INTERRUPTER
PROTECTION
(
or
equivalent;
RCD,
for
export
installs
)
All
PDC
Spas
swim
spas
are
permanently
installed
units.
GROUND
FAULT
CIRCUIT
INTERRUPTER
PROTECTION
IS
REQUIRED.
All
swim
spa
equipment
systems
must
be
protected
by
a
class
A
ground
fault
circuit
interrupter
(GFCI)
or
equivalent;
RCD,
for
export
installs.
A
ground
fault
circuit
interrupter
type
circuit
breaker
(NOT
SUPPLIED)
must
be
installed
in
the
home
panel
box
by
a
licensed
electrician
when
making
wire
connec on
to
the
swim
spa
support
pack
equipment.
DANGER:
RISK
OF
ELECTRICAL
SHOCK:
Install
the
swim
spa
at
least
fi
ve
feet
(1.52
m)
from
all
ungrounded
(unbounded)
metal
surfaces.
Ground
fault
circuit
interrupter
protec on
of
the
home
power
supply
to
the
swim
spa
is
necessary.
Your
electrician
should
explain
how
it
operates.
(See
swim
spa
maintenance
for
func on
and
tes ng)
Do
not
permit
any
electric
appliance,
such
as
a
light,
telephone,
radio
or
television,
within
fi
ve
feet
(1.52
m)
of
a
swim
spa.
Keep
electrical
appliances
and
extension
cords
away
from
the
swim
spa.
Water
is
a
conductor
of
electricity.
DANGER:
RISK
OF
ACCIDENTAL
DROWNING.
Extreme
cau on
must
be
exercised
to
prevent
unauthorized
access
by
children.
To
avoid
accidents,
ensure
that
children
cannot
use
a
swim
spa
unless
they
are
supervised
at
all
mes.
DANGER:
TO
REDUCE
THE
RISK
OF
DROWNING:
1.
Never
use
the
swim
spa
alone.
2.
Children
should
not
use
the
swim
spa
unless
they
are
supervised
by
an
adult
3.
Keep
pets
away
from
the
swim
spa
at
all
mes.
4.
ALWAYS
REPLACE
AND
LOCK
THE
SWIM
SPA
COVER
WHEN
THE
SWIM
SPA
IS
NOT
IN
USE.
READ
AND
FOLLOW
ALL
IMPORTANT
SAFETY
INSTRUCTIONS
When
installing
and
using
this
equipment
basic
safety
precau ons
should
always
be
taken
to
reduce
the
risk
of
electrical
shock,
to
ensure
safe
usage,
and
to
safeguard
the
user’s
health.
Safety Instruc ons
3