background image

Example: 

Model 

Generator rated output 

Frequency 

Power factor 

1 .0 

0.4-0.75 

MG-4502 

2000VA 

0-2000VA 

0-800W - 1 500W 

1 00W 

below 5A 

if 

t

u

r

n

i

ng 

on the Smart Throttle without 

AC current ou

t

p

u

t

• 

W

h

e

charging  batteries, person  must  be present to  monitor the  v

o

l

tage

Stop cha

r

g i

n

when 

the  voltage of the  batteries 

is 

above 

1 6V. Or 

it ma

y  cause  battery  explosion,  res

u

l

t

i

n

in  se

r

i

o

u

injury 

or 

death. 

Charging wires 

To  prevent  the  possibility 

of c

r

e

at

i

ng 

spark 

near the  battery,  connect 

c

h

ar

ging cable 

first 

to 

t

h

e  generator,  then 

to 

the  battery.  Disconnect cable first 

at 

the battery. 

Before connecti

n

charging cables 

to  a  battery  that 

is installed in 

v

e

h

i

cl

e

disconnect 

the  vehicles grounded battery cable.  Reconnect  the  vehicle's grounded  battery  cable 
after 

t

h

c

har

g

i

n

cables are 

removed.  This procedure will p revent the 

possibility 

of 

s

h

o

r

circuit 

and sparks  if you  make accidental  contact between  a 

b

a

t

t

e

ry 

terminal  and 

the vehicle's  frame 

or 

b

od

y

Do  not  attempt to  start an automobile engine while the  generator stil l  

connected  to the 

battery. 

T

h

generator  may  be damaged. 

Connect 

the 

p

os

it

i

ve  battery t

e

r

m

i

n

a

l  to the positive charging 

c

or

d

Do 

not 

re-verse  the 

charging 

cables, 

or 

serious 

damage to 

the 

g

e

n

er

a

t

o

and/or  the  b

a

t

t

e

r

m

a

o

ccu

r

The 

battery gives 

off explosive gases;  keep  spark, flames and ciga rettes 

away.  P

r

o

v

i

d

adequate ventilation when charging. 

The 

battery contains su

l

p

h u

ri

acid 

(electrolyte). 

C

o

nta

c

with 

s

k

in 

or eyes may cause 

severe burns. Wear 

p

rot

e

c

t

i

v

e  clothing and a  face 

shield. 

If electrolyte 

gets 

on 

your 

skin, 

flush with 

w

a

ter

- If 

electrolyte gets in  your  eyes,  flush with  water for at least 

15 

minutes  and  c

a

l

physician . 

E

l

e

c

tr

o

l

y

t

is 

poisonous. 

- -If 

s

w

a

l

lo

w

e

d

drink large quantities 

of 

water or 

milk 

and 

follow with  milk or magnesia or 

v

eget

ab

l

oil 

and call a  physician. 

KEEP OUT OF THE  REACH  OF CHILDREN,  PETS 

AND 

UNTRAINED PEOPLE. 

P a g e  

1 12 

5, 7  Start the engine 

The  DC 

receptacle  may 

be  u sed  whil e  the 

AC 

p

o

w

e

is in  u

s

e

An 

o

ve

rl

o

aded 

DC 

circuit 

will 

trip 

t

he 

DC circuit 

pr

o

t

e

c

t

or

If this 

happens,  disboard the 

DC 

load  before  pushing in the 

c

i

r

c

u

i

protector to  resume operation. 

DC circuit 

breaker 

5.8  Oil alert 

system 

The  oil alert system  is 

designed  to 

prevent engine damage caused 

by 

an 

i nsufficient 

a

m

o

u

nt 

of 

oil 

in 

the 

crankcase. 

B

e

f

o

r

the oil 

level in 

t

h

cra nkcase falls below 

safe 

limit, 

th

oil alert system  will automatically 

shut 

down 

the  engine (the 

e

n

g

ine switch will 

rema in 

in 

the 

ON 

position). 

If 

t

he 

oil 

a

l

e

rt 

system  shuts down 

the 

engine, the o

i

l  alert indicator 

light 

(red) 

will 

come 

on 

when you o

p

e

r

a

te 

the starter, and the 

e

n

g

in

e will not 

run .  

If 

th

i

s  occurs,  a dd  engine oil. 

Oil alarm  indicator (red) 

5.9  Stopping the engine 

To stop 

the 

engine in 

an 

emergency,  turn  the 

en

g

in

switch to 

t

he 

OFF 

position. 

In 

n

o

rm

a

l use: 

1 .  

Switch 

off 

the connected 

equipment and 

pull the  inserted 

p

l

u

out. 

P  a 

9  e 

1 13 

Summary of Contents for MG-4502

Page 1: ... MG 4502 Distributed by Electus Distribution Pty Ltd 320Victoria Road Rydalmere NSW 21 16 Australia Phone 1300 738 555 Facsimile 1300 738 500 www electusdistribution com au Made in China NOTE NeINer versions feature auto choke If you have this model please disregard mention of the choke function in this user manual ...

Page 2: ...ents preceded by the following words AWARNING It indicates a strong possibility of severe personal injury or death if instructions are not followed ACAUTION It indicates a strong possibility of severe personal injury or death if instructions are not followed If a problem should arise or if you have any questions about the generator consult an authorized dealer ABE CAREFUL The generators are design...

Page 3: ...with engine stopped Keep away from Cigarette smoke and sparks when refueling the generator Always refuel in a well ventilated location AWarnin Connection for standby power to a building electrical system must be made by a qualified electrician The connection must isolate the generator from utility power and must comply with all applicable laws and electrical codes I mproper connections to a buildi...

Page 4: ...od 21 FIRE NET OF MUFFLER SERVICE 22 8 TROUBLESHOOTING 23 9 TECHNICAL DATA 25 9 1 9 2 9 3 Size and weight 25 Engine 25 Generator 25 10 Wiring diagram 26 11 Exploded parts view 27 12 Parts list 28 Digital Inverter Generator 2000W Warning Read this manual carefully before using the machine for your own safety Your power tool should only be passed on with these instructionsr COMPONENT IDENTIFICATION ...

Page 5: ...he generator Always refuel in a well ventilated location Wipe up spilled gasoline at once Connections for standby power to a building s electrical system must be made by a qualified electrician and must comply with all applicable laws and electrical codes Improper connections can allow electricat current from the generator to back feed into the utility lines Such back feed may electrocute utility ...

Page 6: ...aded is preferred to minimize combustion chamber deposits Don t use fuel containing alcohol Fuel system damage or engine performance problems resulting from the use of fuels that contain alcohol are not covered under the warranty Never use an oil gasoline mixture or dirty gasoline Avoid getting dirt dust or water in the fuel tank After refuelling tighten the fuel filler cap securely Fuel cap Opoo ...

Page 7: ...ke lever all the way to the left To restart a hot motor set the choke lever half way Choosing the right choke position is the key to starting the motor You may have to practise a few times to use the choke correctly Running Shove the choke completely to the right to restart a hot motor Shove the choke to about halfway to restart a warm motor A hot motor will not start if there is too much fuel In ...

Page 8: ... others who contact the lines during a power outage and when utility power is restored the generator may explode burn or cause fires in the building s electrical system Limit operation requiring maximum power to 30 minutes For continuous operation do not exceed the rated power In either case the total wattage of all appliances connected must be considered Do not exceed the current limit specified ...

Page 9: ...insert the plug of the equipment to be used mto the AC receplacle unit A Check that the equipment to be connected is switch off When the equipment to be used is switched on it will operate suddenly and injuries or accidents may be caused 4 Switch on the equipment output indicator light will glitter light In case of overload operationor when trouble occurs for the equipment being used the output in...

Page 10: ...osive gases keep spark flames and cigarettes away Provide adequate ventilation when charging The battery contains sulphuric acid electrolyte Contact with skin or eyes may cause severe burns Wear protective clothing and a face shield If electrolyte gets on your skin flush with water If electrolyte gets in your eyes flush with water for at least 15 minutes and call a physician Electrolyte is poisono...

Page 11: ... generator P a g e 1 14 Open 6 MAINTENANCE Air vent knob Close The purpose of the maintenance and adjustment schedule is to keep the generator in the best operating condition Inspect or service as scheduled in the table below t Shut off the engine before performing any maintenance If the engine must be run make sure the area is well ventilated The exhaust contains poisonous A carbon monoxide gas i...

Page 12: ... and is mechanically proficient See the Shop Manual Tem rature c Jlme for ehanglng 011 hourI Reeommended l W8r factor 25 100 30 35 40 1 5 12 85 70 6 1 Changing oil Drain the oil while the engine is still warm to assure rapid and complete draining Make sure to turn the engine switch and the fuel cap vent lever OFF before draining 1 Lean the generator 2 Fasten the oil lead pipe on the oil exhaust as...

Page 13: ... access panel 2 Remove the screw under the air filter case 3 Pull the air filter cartridge down 30mm and remove the air filter cartridge 4 Remove the air filter iron clip and check the air filter element Clean or replace the element if necessary 5 Reinstall the air filter parts after cleaninQ or replacinQ air filter element 6 3 Sparkplug servicing Air cleaner case Air cleanerelement Air cleaner ca...

Page 14: ...l the tank there should be no fuel in the filler neck Do not operate the generator while it is on a vehicle Take the generator off the vehicle and use it in a well ventilated place Avoid a place exposed to direct sunlight when putting the generator on a vehicle If the generator is left in an enclosed vehicle for many hours high temperature inside the vehicle could cause fuel to vaporize resulting ...

Page 15: ...a g e l 22 8 TROUBLESHOOTING Engine will not start L _ _ _ _ _ ll N O IAdd fuel No No No Replace spark plug Turn them to the on position Add more qualified oil Start a few times to ensure that fuel enters the carburetor Send the generator to an authorized dealer Shake the generator several times to make the float rise if the generator cannot start after adding oil for the first time and the oil al...

Page 16: ...nition ystem T D I Oil capacity O 45L Fuel tank capacity 7L Spark plug A6 RTC There is no power in the DC electric outlet Is the electric circuit No Replace the electric circuit breaker intact breaker Noise level 7m 60db I Yes Send the generator to an 9 3 Generator authorized dealer Type Item Generator Model No MG 4502 DefiCient AC output I Deficient output I Rated voltage V 110 120 230 240 Rated ...

Page 17: ...RAM i r i u 4 i I I i til I I J u Vrs If li I I I I I I t s I L 1 __ L_ L _ _ _ _ _ _ _ _ _ _ _ L I JJ i J f _ E f I 1 i P a g e l 26 i f f I l I i j I f i li 1 I r EXPLODED PARTS VIEW 1 I 1 I _1 1 I P a g e l 27 ...

Page 18: ...uum pump 66 Control panel 25 Carburetor connecting flange 6 7 M4 x 1 0 self taping screw 26 Sheet iron clasp 68 M5 nut 27 Foat outer shroud 69 Access panel 28 Chassis 70 Right shroud 29 Shock absorption foot 71 Breathing tube 1 30 M6 x 20 flange bolt 72 Air cleaner breathing tube 31 Ignition Coil 73 Wind shield 32 M6 x 15 flange bolt 74 Right fan shield 33 Ignition Coil bracket 75 Muffler bracket ...

Reviews: