Chapter 6 Description of Function Codes
-159-
Function
code
Name
Description
(setting range)
Factory
Default
Change
F09.13
Reverse control
0: enabled
1: disabled
0
※
It is used to set whether the AC drive allows reverse rotation. In the applications where reve-
rse rotation is prohibited, set this parameter to 1.
Function
code
Name
Description
(setting range)
Factory
Default
Change
F09.14
Running mode when set
frequency lower than
frequency lower limit
0:run at frequency
lower limit
1: stop
2: run at zero speed
0
※
It is used to set the AC drive running mode when the set frequency is lower than the
frequen-
cy lower limit. The provides three running modes to satisfy requirements of various applic-
ations.
If the accumulative power-on time (F7-13) reaches the value set in this parameter, the corre
-
sponding DO terminal becomes ON.
Function
code
Name
Description
(setting range)
Factory
Default
Change
F09.15
Accumulative power-on time
threshold
0.0s
~
6500.0s
0h
※
Function
code
Name
Description
(setting range)
Factory
Default
Change
F09.16
Accumulative running time
threshold
0.0s
~
6500.0s
0h
※
It is used to set the accumulative running time threshold of the AC drive. If the accumulative
running time (F08.10) reaches the value set in this parameter, the corresponding DO termin-
al becomes ON.
C
h
a
p
te
r
6
Function
code
Name
Description
(setting range)
Factory
Default
Change
F09.17
Startup protection
0: No
1: Yes
0
※
Peaco Support FC280 Series VFD User Manual