Command Address
Command Function
1004H
0
~
7FFF means 0%
~
100%
Pulse output control: (only write)
Status address
Status Command Function
2000H
0001: forward running
0002: reverse running
0003: stop
Read AC drive status: (only write)
Chapter 8 Appendix
-209-
Stop/run parameter address:
Address
Data meaning
Addres
Data meaning
3000H
*
communication setting range
(-
10000
~
10000
)(
decimalism
)
3001H
frequency running
3002H
bus voltage
3003H
output voltage
3004H
output current
3005H
output
3006H
output torque
3007H
speed
3008H
terminal input symbol
3009H
terminal output symbol
300AH
Ai1 voltage
300BH
Ai2 voltage
300CH
Ai3 voltage
300DH
count value input
300EH
length valuse input
300FH
load speed
3010H
PID setting
3011H
PID feedback value
3012H
PLC steps
3013H
input pulse frequency
,
unit is
0.01kHz
3014H
feedback speed
,
unit is 0.1Hz
3015H
residue running time
3016H
Ai1 voltage before correcting
3017H
Ai2 voltage before correcting
3018H
Ai3 voltage before correcting
3019H
line speed
301AH
current power on time
301BH
current run time
301CH
input pulse frequency
,
unit is 1Hz
301DH
communication setting time
301EH
actual feedback speed
301FH
A frequency display
3020H
B frequency display
C
h
a
p
te
r
8
Peaco Support FC280 Series VFD User Manual