Chapter 8 Appendix
C
h
a
p
te
r
8
-231-
C
h
a
p
te
r
8
Model ( 380V)
Max DC input
current ( A)
Rated output
current ( A)
Applicable water
pump ( KW)
4T0055G/0075P
23.9
14.0
5
.
5
4T0075G/0110P
30.6
17.0
7
.
5
4T0110G/0150P
39.2
25
11
4T0150G/0185P
49
32
15
3. Installation and Commissioning Instructions for Photovoltaic Water Pumps
3.1 Wiring:
1st type:
the positive pole of the solar photovoltaic panel output is connected to the inve-
rter "+" terminal, and the negative pole of the solar photovoltaic panel output is
connected to the inverter "-" terminal.
2nd type:
solar photovoltaic The positive and negative poles of the board output are resp-
ectively connected to the "R" and "T" terminals of the inverter. This method does
not distinguish between positive and negative. The water pump is connected to
the “U” “V” “W” terminals of the inverter.
Peaco Support FC280 Series VFD User Manual
www.peacosupport.com sales@peacosupport.com Free Shipping Worldwide Reliable Supplier
PEACO SUPPORT