Function
code
Name
Description
(setting range)
Factory
Default
Change
F09.24
Detection range of
frequency reached
0.0%
~
100.0%( F00.03 (
max. frequency) )
0.0%
※
F09.25
Jump frequency during
acceleration/deceleration
0: disabled
1: enabled
0
※
F09.28
Frequency switchover point
between acceleration time 1
and acceleration time 2
0.00Hz
~
F00.03( max.
frequency)
0.00Hz
※
F09.29
Frequency switchover point
between deceleration time 1
and deceleration time 2
0.00Hz
~
F00.03( max.
frequency)
0.00Hz
※
F09.30
Terminal JOG preferred
0: disabled
1: enabled
0
※
F09.31
Any frequency reaching
detection value 1
0.00Hz
~
F00.03( max.
frequency)
50.00Hz
※
F09.32
Any frequency reaching
detection amplitude 1
0.0%
~
100.0%( F00.03(
max. frequency)
0.0%
※
F09.33
Any frequency reaching
detection value 2
0.00Hz
~
F00.03( max.
frequency)
50.00Hz
※
F09.34
Any frequency reaching
detection amplitude 2
0.0%
~
100.0%( F00.03(
max. frequency)
0.0%
※
F09.35
Zero current detection level
0.0%
~
300.0%( rated
motor current)
5.0%
※
F09.36
Zero current detection delay
time
0.01s
~
600.00s
0.10s
※
F09.37
Output overcurrent
threshold
1.1% (no detection)
1.2%–300.0% (rated
motor current)
200.0%
※
F09.38
Output overcurrent detectio
delay time
0.00s
~
600.00s
0.00s
※
F09.39
Any current reaching 1
0.0%
~
300.0%
((
rated
motor current
)
100.0%
※
F09.40
Any current reaching 1
amplitude
0.0%
~
300.0%
(
rated
motor current
)
0.0%
※
F09.41
Any current reaching 2
0.0%
~
300.0%
(
rated
motor current
)
100.0%
※
F09.42
Any current reaching 2
amplitude
0.0%
~
300.0%
(
rated
motor current
)
0.0%
※
Chapter 5 Function & Parameter Table
-72-
C
h
a
p
te
r
5
Peaco Support FC280 Series VFD User Manual
www.peacosupport.com sales@peacosupport.com Free Shipping Worldwide Reliable Supplier