4. Connect the air source (air pressure 5kg/cm
2
-8kg/cm
2
), Adjust the air pressure to
0.4~0.6MPa
(See Fig. 26)
.
D. Install electric system
1. Adjusting the current rating of thermal relay in control box according to the different
configurations of hydraulic power unit. In general, the electric current of thermal
relay should equal or larger than that of motor. The following table shows rated
current regulation of thermal relay in case of different hydraulic power unit.
Hydraulic power unit
Single phase
/4.0HP
Three phase
/4.0HP
Rated current of thermal relay
22A
14A
Clockwise to increase the air pressure
Counter-clockwise to reduce the air pressure
Adjust the air pressure to 0.4~0.6MPa
Adjust the air pressure
to 0.4~0.6MPa
Fig. 26
Fig. 27
This point shows
the present rated
current value
Using cross
screwdriver to adjust
rated current value of
thermal relay
Connect air
source
14