NM360L- Nitrogen Gas Generator
UM – NM360L
AIR CONNECTION
The Nitrogen Generator should be connected to a
clean, dry, OIL - FREE
source of compressed air. A minimum pressure of 120 psig is required for
efficient operation of the Generator. Any doubts as to the suitability of your
compressed air supply should be referred to the factory for advice.
A MAXIMUM OIL VAPOUR CONTENT OF 5 mg per m^3 is PERMISSIBLE
Air Inlet and Nitrogen Outlet connections are at the rear of the generator in the
middle right side of the panel. The Air inlet connection is the left port. 1/2” BSP
female, outlet port is 3/8” BSP female. The generator is supplied with two
Breathing Air
pre-filters and an
Activated Carbon
post filter, which are fitted
internally. The
Breathing Air
filters will drain moisture and are equipped with
automatic drains. This is connected to the 1/4” BSP Female port at the bottom
of the rear panel. Any bulk moisture in the inlet air will be trapped by these
filters and released through this drain port, which should be led to a
convenient place.