background image

3.

AC voltage detection

The probe tester inserted into the power socket or close to the live wire

When the tester detects the AC

voltage signal, the induction voltage signal lamp flashes

According to the detected signal strength, the

tester can illuminate the corresponding signal intensity indicator (high, middle, low)

At the same time,

the buzzer sends out different alarm sounds

When the AC voltage signal is sensed, Low signal intensity

indicator is lit

When sensing a higher AC voltage signal

Light up the signal intensity indicator (middle,

low) at the same time

When the highest AC voltage signal is sensed, the signal intensity indicator (high,

middle, low) is also lit

4.

Zero/live wire judgment

Try to separate the two wires to be detected as far as possible

Then close the wire with the probe of the

tester

If it is a socket, insert the probe into the socket

One of the strong signals detected by a tester is

live wire

a weak or no inductive signal is zero wire

5.

Auto Power Off

When the tester does not operate for about 5 minutes and the voltage signal is not detected, the tester

will turn off automatically

6.

Low battery indication

When the battery voltage is lower than about 2.6V, the power indicator flashes 3 times, and the buzzer

beeps and shuts off automatically. Please replace the battery in time

Specifications

AC voltage range

About 12 ~1000V

Frequency

50 Hz /60Hz

Alarm mode

Sound and light alarm

Torch

White LED illumination lamp

Auto power off

Low battery indication

Zero/live wire judgment

According to the signal strength, strong signal is live wire

NCV intensity

Selecting 3 types of sensitivity automatically (low, mid, high)

NCV intensity indication

The instrument uses the alarm sound of different frequency and LED lamp of different

color to indicate low, moderate or high sensitivity

Service temperature

0~40

Storage temperature

-10~50

Altitude

<2000m

Security level

CE CAT.III 1000V /CAT.IV 600V

Power

2×1.5V AAA batteries

Size

156mm×20mm×20mm

Weight

About 45g

Battery replacement

As per the diagram below

1.

Rotate the battery cover

2.

Take out the used battery

3.

Put new battery in as per battery anode and

cathode indication

Warning: To avoid electric shock, do not use this

instrument before the battery cover is replaced.

Battery rotation direction

as indicated