3.3.5. Use of Memory Function ( Store / Recall Mode )
While performing a complicated test where instrument setting needs be changed frequently, 100
instrument settings of Freq(F)+Level(L)+Mod(M) combinations can be stored at 100 internal memory
addresses and 4 frequently used levels at A, B, C, D keys.
3.3.5.1. Storing Address
1)
Set an address to store data( refer to 3.3.4 ).
2)
Set Frequency, Level and Modulation data.
3)
Press
,
key
4)
Front panel display will blink once indicating acceptance.
☞
☞
☞
☞
In case ‘Sequential Recall Mode’ is on, data may change whenever a new address is entered
and this may be annoying.
Then, just turn off ‘Sequential Recall Mode’ by pressing
key (Refer to 3.3.5.5 )
3.3.5.2. Recalling Address
1)
Set an address to recall (refer to 3.3.4) .
2)
Press
key
☞
☞
☞
☞
Be sure that ‘Sequential Recall Mode’ is turned off.
3.3.5.3. Storing Preset Levels at A-B-C-D keys
1)
Enter a desired level.
2)
Press
Key. Now it is ready to store.
3)
Press
, (
,
or
) key.
‘Level Display’ blinks once indicating the operation is completed.
3.3.5.4. Recalling Preset Levels from A-B-C-D keys
Simply
, ( or
,
,
) key.
The preset level output to the RF output connector.
3.3.5.5. Sequential Recall
1)
‘Sequential Recall Mode ’ is active when the
key LED is on.
2)
By increasing and decreasing ADDRESS using
,
keys, the desired memory address
can be accessed and the data stored at the address is output. Direct entry of the address
value with numeric key will do the same.
3.3.6. Special Maintenance Functions using
key
3.3.6.1 DISPLAY test (
,
)
1)
Press
,
key turns on all the display. The purpose of this function is to test DISPLAY.
First check in all the display segments are on.
2)
Press any key of ‘Front Panel’ keys, then turn off the segments one by one.
3.3.6.2. Default settings (
,
,
)
1)
Press
,
,
key
Performing this keying sequence sets the default values and displays "InItIAL" on FREQ
window. The factory default values are shown in Table 3-1. This function is intended for factory
use only.
☞
☞
☞
☞
Be careful since all the memory contents will be lost.