56
connect to the diode
’s anode, and the black test lead is
connected to the diode’s cathode. This meter supplies
enough forward voltage to light most LED´s. However, if the
LED’s forward voltage is greater than 2.0 volts, the meter
incorrectly indicates that the device is open.
6.9. Checking Continuity
Follow these steps to check a circuit’s continuity.
1. Set the rotary selector to
2. Press select until Continuity symbol
is shown
2. Plug t
he black test lead into your meter’s COM terminal
and the red test lead into your meter’s V/
/Hz/-
terminal.
3. Remove power from the circuit.
4. Connect the test leads to the circuit.
Note:
The buzzer sounds if the measured resistance is below
about 50
approximately.
Warning!
Never perform a continuity measurement on a
circuit that has power connected.