6. mA Input Jack
The mA jack is used for AC and DC currents up to 400mA, and the
temperature measurement. Connect mA current measurements with the
red lead to this terminal and for temperature measurement the
connector of the temperature sensor / adapter. This range is protected
by a 500mA fuse against overload.
7. 10A Input Jack
The 10A jack is used for AC and DC currents up to 10A up with
measurement up to 10 seconds once every 15 minutes. Connect the red
lead for current measurements with this jack. This range is protected by
a 10A fuse against overload.
8. V/
/CAP/Hz Input Jack
To connect the red test lead for voltage, resistance, capacitance and
frequency measurements, as well as for the measurement functions
diode and continuity tests.
9. COM Input Jack
To connect the black test lead (all measurement functions).
10. REL Key
The relative value measurement function allows the measurement and
display of signals considering to a defined reference value. Press the
REL key 1 x and the displayed value is set to 0. Wherein a reference
value of 100V for example, and an actual measurement value of 90V, in
the
LCD display -010.0V appears. If reference value and measured value
are the same, the digital display shows the value of "0."
11. Hz / Duty Key
Pressing this button toggles the frequency measurement function to
measure the duty cycle. The display shows the ratio of high to low pulse
in percent.
12. Hold / Backlight Key
The Hold / Backlight key is used to activate the data hold function by
pressing the key once. The current measured value is retained in the
display until the button is pressed again. Keep the button pressed for a 2
seconds and the backlight of the LCD display is activated. This turns off
automatically after about 20 seconds.