5.3. Additional functions
1.) Output button
-
Press [Output] to activate the output and outputting the set values.
-
or press [Output] to disable the output. (Default setting: output is disabled after turning
the unit on).
2.) Key lock
The device has a key lock which the accidentally change the output voltage - or prevents the
output current.
-
To activate the key lock, the [.] - Button for 3 seconds and hold. You will hear a
confirmation tone.
-
To deactivate the key lock again, - press and hold again for 3 seconds [.] until a
confirmation tone is emitted.
3.) Correction key [Del]
-
If it comes to an incorrect entry, while entering the voltage - or current value and the
[Enter] button is not pressed, then the actual entry could be rejected by pressing the
[Del] key. The display switches back to the beginning of 0.000 (first digit flashes).
6. CAUTION
In the event of a short circuit at the output the current will limit at the value set by the current
controls, however the unit should be turned off and the short circuit removed before
continuing use.
The mains power must be switched off before servicing and servicing should be referred to a
qualified person.
The unit should be stored in a dry and well ventilated place and the power cord removed if
storing for long periods.
If the unit is not a long time in use, unplug the power connector from the device
-15-