background image

ENGLISH

IMPORTANT SAFETY INSTRUCTIONS 

WARNING:

 When using electrical products, basic cautions should always be followed, including the following:

1. 

Read these instructions. 

2.  

Keep these instructions.

3. 

Heed all warnings.

4. 

Follow all instructions.

5. 

Do not use this apparatus near water. 

6. 

Clean only with a dry cloth.

7. 

Do not block any of the ventilation openings. Install in accordance with manufacturer’s instructions. 

8. 

Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including amplifiers) that 

produce heat.

9. 

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than 

the other. A grounding type plug has two blades and a third grounding plug. The wide blade or third prong is provided for your 

safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 

10.  

Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point they exit 

from the apparatus.

11. 

Only use attachments/accessories provided by the manufacturer.

12. 

Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is 

used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

13. 

Unplug this apparatus during lightning storms or when unused for long periods of time.

14. 

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such 

as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has 

been exposed to rain or moisture, does not operate normally, or has been dropped.

15. 

Never break off the ground pin. Write for our free booklet “Shock Hazard and Grounding.” Connect only to a power supply of the 

type marked on the unit adjacent to the power supply cord.

16. 

If this product is to be mounted in an equipment rack, rear support should be provided.

17. 

Note for UK only: If the colors of the wires in the mains lead of this unit do not correspond with the terminals in your plug‚ 

proceed as follows: a) The wire that is colored green and yellow must be connected to the terminal that is marked by the letter 

E‚ the earth symbol‚ colored green or colored green and yellow. b) The wire that is colored blue must be connected to the 

terminal that is marked with the letter N or the color black. c) The wire that is colored brown must be connected to the terminal 

that is marked with the letter L or the color red.

18. 

This electrical apparatus should not be exposed to dripping or splashing and care should be taken not to place objects 

containing liquids, such as vases, upon the apparatus.

19. 

The on/off switch in this unit does not break both sides of the primary mains. Hazardous energy can be present inside the 

chassis when the on/off switch is in the off position. The mains plug or appliance coupler is used as the disconnect device, the 

disconnect device shall remain readily operable.

20. 

Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably in susceptibility to 

noise-induced hearing loss, but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a sufficient 

time. The U.S. Government’s Occupational Safety and Health Administration (OSHA) has specified the following permissible 

noise level exposures:

 

Duration Per Day In Hours 

Sound Level dBA, Slow Response

 

 

90

 

 

92

 

 

95

 

 

97

 

 

100

 

 

1 1⁄2 

102

 

 

105

 

 

1⁄2 

110

 

 

1⁄4 or less 

115

According to OSHA, any exposure in excess of the above permissible limits could result in some hearing loss. Earplugs or protectors to 

the ear canals or over the ears must be worn when operating this amplification system in order to prevent a permanent hearing loss, if 

exposure is in excess of the limits as set forth above. To ensure against potentially dangerous exposure to high sound pressure levels, it is 

recommended that all persons exposed to equipment capable of producing high sound pressure levels such as this amplification system be 

protected by hearing protectors while this unit is in operation.

SAVE THESE INSTRUCTIONS!

Summary of Contents for QF 151

Page 1: ...www peavey com Operating Manual QF 231 QF 151 Graphic Equalizers ...

Page 2: ...rée par l utilisateur Confiez I entretien et la réparation de l appareil à un réparateur Peavey agréé AVIS Dans le but de reduire les risques d incendie ou de decharge electrique cet appareil ne doit pas etre expose a la pluie ou a l humidite et aucun objet rempli de liquide tel qu un vase ne doit etre pose sur celui ci Avant d utiliser de cet appareil lisez attentivement le guide fonctionnant pou...

Page 3: ...ack rear support should be provided 17 Note for UK only If the colors of the wires in the mains lead of this unit do not correspond with the terminals in your plug proceed as follows a The wire that is colored green and yellow must be connected to the terminal that is marked by the letter E the earth symbol colored green or colored green and yellow b The wire that is colored blue must be connected...

Page 4: ...te verwijdering van dit product Deze markering geeft aan dat dit product nergens in de Europese Unie met ander huishoudelijk afval mag worden afgevoerd Om mogelijke schade aan het milieu of gezondheid door ongecontroleerde afvalverwijdering te voorkomen recycle het op een verantwoorde wijze om het duurzame hergebruik van materiaalgrondstoffen te bevorderen Om uw gebruikte apparaat in te leveren ku...

Page 5: ...and 2 this device must accept any interference received including interference that may cause undesired operation Warning Changes or modifications to the equipment not approved by Peavey Electronics Corp can void the user s authority to use the equipment Peavey Electronics Corporation 5022 Hartley Peavey Drive Meridian MS 39305 601 483 5365 FAX 601 486 1278 www peavey com 2012 ...

Page 6: ... equipment Features QF 215 Dual channel 15 bands per channel 2 3 octave filter sets ISO center frequencies within 3 accuracy 25 Hz to 16 kHz effective equalization range 45 mm center detent control sliders enclosed in metal for durability Constant Q filters Output level LEDs 12 to 12 dB 12 dB boost 18 dB cut per band 18 dB per octave 40 Hz low cut filter with status LED 15 dB gain control Improved...

Page 7: ...ols adjust the amount of cut or boost at their respective frequencies They are adjustable from 18 dB cut to 12 dB boost For units equipped with FLS the LED at the top of each band will illuminate as an indication of feedback at that frequency Low cut filter This switch activates the low cut filter that rejects frequencies below 40 Hz Frequency roll off is 24 dB per octave with the switch engaged T...

Page 8: ...g proceed as follows 1 The wire that is colored green and yellow must be connected to the terminal that is marked by the letter E the earth symbol colored green or colored green and yellow 2 The wire that is colored blue must be connected to the terminal that is marked with the letter N or the color black 3 The wire that is colored brown must be connected to the terminal that is marked with the le...

Page 9: ...QF Series Block Diagram ...

Page 10: ...e 660 ohms Maximum Input Level 18 dBV 8 V RMS Maximum Output Level 18 dBV unbalanced 21 dBV balanced Nominal Input Level 0 dBV 1 V RMS Nominal Output Level 0 dBV 1 V RMS Input Headroom Nominal 18 dB Output Headroom 18 dB Maximum Boost and Cut Gain 15 dB 15 dB Low Cut Filter 40 Hz 24 dB per octave Power Consumption Domestic 120 VAC 60 Hz 12 Watts Export 220 230V 50 60 Hz 12 Watts Dimension 3 5 89 m...