Output Level LED Meter
This LED array indicates output level from –12 dB to +12 dB.
Gain
This calibrated, detented control regulates overall gain of the EQUALIZER SECTION (3). Unity gain throughout the
signal chain can be maintained by recovering lost signal gain at this point. The equalization process may result in
noticeable signal loss. To compensate for this loss, engage the BYPASS (5) switch and compare the signal level with
that of the equalized level. Increase the GAIN control until the equalized level approximates that of the bypassed
level. Let your ears be your guide.
Equalizer Section
These calibrated, detented controls adjust the amount of cut or boost at their respective frequencies. They are
adjustable from 18 dB cut to 12 dB boost. For units equipped with FLS
®
, the LED at the top of each band will
illuminate as an indication of feedback at that frequency.
Low-cut filter
This switch activates the low-cut filter that rejects frequencies below 40 Hz. Frequency roll off is 24 dB per octave
with the switch engaged. This filter will operate even with the BYPASS (5) switch engaged. The adjacent red LED
indicates activation.
Bypass
This switch allows the signal to bypass the unit with the exception of the LOW-CUT FILTER (4). When this switch is
engaged, the signal is routed from INPUT (10 and 11) through the low-cut filter to output (8 and 9).
Power LED
The green LED indicates activation.
F R O N T P a N E L
1
1
2
2
3
3
1
2
3
5
5
4
4
5
4
1
2
3
4
5
6
6
6