Mashing 

 
After filling with the required volume of water, plug in to the mains supply and switch on. The display module should illuminate to indicate that power is being 
supplied it.    The  current  sensor  temperature  will  be  displayed.    The  set  temperature  of  the  thermostat  is adjusted by  momentarily  pressing  ‘P’.   ‘SP’ will  be 
displayed  alternating  with  the  current  set  temperature.    This  is  factory  set  to  0.    Use  the 

and 

buttons  to  adjust  the  temperature.    The  maximum  and 

minimum  settings  are  101  and  0  respectively.    Set  the  display  to  60  and  then  momentarily  press  ‘P’.    The  display  will  revert  to  showing  the  current  water 
temperature  and  the  red  ‘Output’  light  in  the  upper  left  hand  corner  of  the  display  will  illuminate.    The  water  will  rapidly  heat  to  60°c  at  which  point  the 
thermostat  will  switch  the  element  off.    Due  to  latent  heat  in  the  element,  the  temperature  will  continue  rising  before  dropping  back  to  59.9°c  when  the 
element will switch on again.  After a few on/off cycles the temperature will stabilise to within approximately ±1°c of the set temperature.  When you wish to 
increase the temperature, momentarily press ‘P’ and adjust to the desired setting, remembering to press ‘P’ again after the setting has been changed.  The use 
of a mashing/sparging bag is strongly recommended to stop the possibility of grain caking and burning on the element.  Always stir the mixture to ensure an 
even temperature.    If  a  mashing  bag  is not  being  used,  the  ingredients  must  be  added SLOWLY  over  at  least  5  minutes,  stirring  continuously.    When adding 
ingredients such as molasses, it is advisable to put the unit in ‘Standby Mode’ by pressing and holding 

U

 for 1 second.  This will switch the element off.  The 

display will go blank and a red light will be shown in the lower right hand corner.  Add the ingredients in the area opposite the element to further reduce the risk 
of  burning  them  onto  the  element.    The  module  is  brought  out  of  ‘Standby  Mode’  by  pressing  and  holding 

U

  again  for  1  second,  when  the  previous  set 

temperature will be resumed and the display will again show the current water temperature. 
 

BOILING AND SIMMERING 
 
! CAUTION – boiling liquid is dangerous.  The bin should be used on the floor.  Do not fill to the top of the bin.  Do not stand the bin on chairs or tables.  Keep 
children and pets well away.  Remember that hot liquids will soften plastic and therefore extreme care must be taken not to knock the tap or element to 
avoid the possibility of causing leaks. 
 

To achieve a vigorous rolling boil, adjust the set temperature to the maximum 105°c by momentarily pressing ‘P’ and using the 

 and 

buttons, remembering 

to press ‘P’ again after the setting has been changed.  The time taken to boil 5 gallons of cold water is approximately 1 hour 20 minutes, or approximately 30 
minutes from mashing temperature.  To simmer, the set temperature should be adjusted to between 97-99°c.  You can leave the liquid to simmer for any length 
of time.  If the lid is fitted, ensure the air hole is kept clear to allow steam to escape. 
 

CLEANING 

 
Always remove the plug from the main supply before cleaning.  The tap and element can be removed for cleaning, but you may find it easier to thoroughly rinse 
out with clean water and wipe dry rather than disturb the rubber washers.  The bin should always be sterilised before use.  The control module MUST NOT be 
immersed in water for cleaning. 
 

WIRING INSTRUCTIONS 

 
The Appliance is fitted and tested with a standard 13 amp plug by the manufacturer.  If the plug has been removed or needs replacing, proceed as follows:- 
 
The wire that is coloured blue must be connected to the terminal that is marked with the letter N or coloured black.  The wire that is coloured brown must be 
connected to the terminal that is marked with the letter L or coloured red.  The wire that is coloured green and yellow must be connected to the terminal that is 
marked  with  the  letter  E  or  coloured  green.    If  a  13  Amp  plug  is  being  used,  a  13  Amp  fuse  must  be  fitted  whether  in  the  plug  or  the  adapter  or  at  the 
distribution board. 
 
The supply cord is a Type Y attachment. If this is damaged, the complete control unit must be returned to the manufacturer or appointed agent.  If the moulded 
plug has been removed, it should be destroyed to prevent a risk of electric shock. 
 

GUARANTEE & PARTS REPLACEMENT 

 
Your Electrim Bin is guaranteed for one year.  Please retain proof of purchase date.  In the event of component failure, it may be quicker for you to contact Peco 
Services Ltd direct for a replacement, this will not affect your statutory rights with the dealer from which you purchased the Bin. 
 
It will not be necessary for you to return the complete Bin, unless the Bin itself has split.  For example, if the tap develops a leak, or the element fails remove it 
and return to the supplier. 
Peco Services Ltd reserves the right to replace or repair parts at its own discretion.

 

 

O

ther home brew products from Peco Services

 

 
Fermenting Trays – for improved quality and reduced fermentation time 
Immersion Heater – Adjustable temperature control for fermentation

 

 

Peco Services Ltd 

Helbeck Road 

Brough 

Cumbria, CA17 4BG 

Tel/Fax: 017683 41111 

 

info@pecoservices.co.uk 

www.pecoservices.co.uk 

 
 
 

E31

 

Reviews: