background image

4 of 7

ISSUED: 01-15-11  SHEET #: 120-9104-2  06-13-11

Visit the Peerless Web Site at www.peerlessmounts.com

For customer care call 1-800-865-2112

In-wall box (

A

) can be installed between two studs 

16" off center. Use a stud fi nder to locate the 
edges of the studs. Use of an edge-to-edge stud 
fi nder is highly recommended. Based on its edges, 
draw two vertical lines down the inside edges of 
the studs. Mark desired center of in-wall box. Draw 
a horizontal line 4-15/16" (125mm) above desired 
center of in-wall box. Draw a second horizontal 
line 9-3/4" (247mm) below this line to outline wall 
opening between inside edges of studs. Remove 
drywall inside cut outline.

Insert in-wall box (

A

) into wall until fl ange is fl ush 

with drywall as shown in fi g. 1.1.

Level in-wall box, and mark center of the four 
mounting holes. Make sure that the mounting 
holes are on stud centerlines. Drill four 3/16" 
(5mm) dia. holes 1-1/2" (38mm) deep. Make sure 
in-wall box is level, and secure it using four wood 
screws (

B

) as shown in fi g. 1.2.

Installation to Wood Stud Wall

1

•  Installer must verify that the supporting surface will safely support the combined load of the equipment and all 

attached hardware and components.

•  Tighten wood screws so that in-wall box is fi rmly attached, but do not overtighten. Overtightening can damage the 

screws, greatly reducing their holding power.

•  Never tighten in excess of 80 in. • lb (9 N.M.).

•  Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud fi nder 

is highly recommended.

•  Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. 

Installers are responsible to provide hardware for other types of mounting situations. 

 WARNING

fi g. 1.1

A

FLANGE

B

fi g. 1.2

9-3/4"

(247mm)

13-1/8"

(333mm)

STUDS

TOP LINE OF CUT 

OUTLINE

CENTER OF 

IN-WALL BOX

4-15/16"

(125mm)

Summary of Contents for IBA2AC

Page 1: ...sembly Recessed Cable Management and Power Storage Accessory Box Models IBA2AC IBA2AC W ISSUED 01 15 11 SHEET 120 9104 2 06 13 11 2300 White Oak Circle Aurora Il 60502 800 865 2112 Fax 800 359 6500 www peerlessmounts com ...

Page 2: ...d components If mounting to wood wall studs make sure that mounting screws are anchored into the center of the studs Use of an edge to edge stud finder is highly recommended Tighten screws firmly but do not overtighten Overtightening can damage the items greatly reducing their holding power This product is intended for indoor use only Use of this product outdoors could lead to product failure and ...

Page 3: ...rated IBA2AC IBA2AC W Description Qty Part Part A in wall box 1 120 P1185 120 2185 B 1 1 2 wood screw 4 500 1090 500 4090 C 4mm security driver 1 560 1133 560 1133 D cable bushing 1 590 1295 590 2295 E cable management clips 2 590 1166 590 1166 F plastic finishing cap 1 590 1123 590 2123 G cable tie 2 590 1168 590 1168 H access plate 1 120 P1187 120 2187 I M5 x 6mm phillips screw 5 520 1023 520 22...

Page 4: ...the mounting holes are on stud centerlines Drill four 3 16 5mm dia holes 1 1 2 38mm deep Make sure in wall box is level and secure it using four wood screws B as shown in fig 1 2 Installation to Wood Stud Wall 1 Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components Tighten wood screws so that in wall box is...

Page 5: ...tor J to outlet box K with access plate H in between using two surge protector screws Attach cover plate to surge protector using two cover plate screws NOTE Service of an electrical gang box and wiring shall be performed by a qualified service personnel in accordance with the NEC Electrical Outlet Installation 2 ACCESS PLATE KNOCKOUT SURGE PROTECTOR SCREWS COVER PLATE SCREWS COVER PLATE H J K H ...

Page 6: ...n the in wall box as shown in figure 3 2 for routing cables Insert cable bushing D into in wall box for routing cables through in wall box Plastic finishing cap F may also be used if cable management is unnecessary Use cable ties G to secure cables to cable management clips as shown in figure 3 3 Cable Management 3 E D or F G CABLES fig 3 2 fig 3 3 fig 3 1 2011 Peerless Industries Inc All rights r...

Page 7: ...erson who is not authorized for such service or repairs by Peerless b the failure to utilize proper packing when returning the product c incorrect installation or the failure to follow Peerless instructions or warnings when installing using or storing the product or d misuse or accident in transit or otherwise including in cases of third party actions and force majeure In no event shall Peerless b...