4
2019-09-26 #:180-9135-4 (2020-08-25)
Power Consumption
(Wattage)
Active Enclosure
Temperature Differential
20W
Δ -6.54 °C (-11.77°F)
30W
Δ -3.05 °C (-5.49 °F)
40W
Δ -0.98 °C (-1.76 °F)
50W
Δ 0.54 °C (-0.97 °F)
60W
Δ 2.68 °C (4.82 °F)
Your device will run at a higher or lower temperature than the outside ambient temperature. To verify your
device will function under typical operating conditions, consult the device's manual to identify and record the
power consumption ( _______ wattage)
and
maximum operating temperature (_______ °)
.
Use chart below to determine the active enclosure temperature differential based on your device(s) power
consumption (wattage).
For example, if your device has a 20W power consumption, the temperature inside the active enclosure will
be -6.54°C (-11.77°F) lower than the outside ambient temperature. This temperature must not exceed the
manufacturer specified maximum operating temperature for your device.
ENG
OPERATING PARAMETERS
ENG -
If active enclosure temperature exceeds device's
maximum temperature, the product may be damaged or
destroyed, voiding the warranty.
CAUTION
Device(s) (not included)
Active Enclosure
20 Watts
30 Watts
40 Watts
50 Watts
60 Watts
-8 C°
-14.4 F°
-6 C°
-9.4 F°
-4 C°
-4.4 F°
-2 C°
0 C°
0.6 F°
2 C°
4 C°
5.6 F°
68 BTU
102 BTU
136 BTU
Load in watts and BTU
Temperature Differential vs. Load
Temperature Differential
171 BTU
205 BTU
Summary of Contents for XACE-01
Page 8: ...8 2019 09 26 180 9135 4 2020 08 25 2 1 2 2 ENG loosen Remove ENG ...
Page 11: ...11 2019 09 26 180 9135 4 2020 08 25 Remove cable gland and save hardware ENG 5 B ...
Page 21: ...21 2019 09 26 180 9135 4 2020 08 25 This page intentionally left blank ENG ...
Page 22: ...22 2019 09 26 180 9135 4 2020 08 25 This page intentionally left blank ENG ...
Page 23: ...23 2019 09 26 180 9135 4 2020 08 25 This page intentionally left blank ENG ...