background image

6 of 13

ISSUED: 06-05-06  SHEET #: 202-9142-4 12-06-06

• Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached

hardware and components.

• Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the

screws, greatly reducing their holding power.

• Never tighten in excess of 80 in. • lb (9 N.M.).

• Do not attach directly to a metal stud wall. Use of a triple stud WSP wall plate is required for attachment to metal

studs (contact customer care). Metal stud installation is not UL evaluated.

• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder is

highly recommended.

• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers

are responsible to provide hardware for other types of mounting situations.

• Never exceed the Maximum UL Load Capacity of 200 lb (91 kg).

1

WARNING

Installation to Wood Stud Wall

Wall plate (A) can be mounted to two studs that are 16" apart. Use a stud finder to locate the edges of the studs.
Use of an edge-to-edge stud finder is highly recommended. Based on their edges, draw a vertical line down each
stud’s center. Place wall plate on wall as a template. The top mounting slots should be located .43" below the
desired screen center. Level plate, and mark the center of the eight mounting holes. Make sure that the mounting
holes are on the stud centerlines. Drill eight 7/32" dia. holes 3" deep. Make sure that the wall plate is level, secure it
using eight 5/16 x 3" wood screws (O) and washers (P).

Skip to step 2 on page 8.

A

O

P

• Never mount this product to metal studs without the

required accessory.

WARNING

Summary of Contents for PLAV 70-UNL

Page 1: ...vel Double Arm for 42 60 Plasma Screens Maximum UL Load Capacity 200 lb 91 kg This product is UL Listed It must be installed by a qualified professional installer R 3215 W North Ave Melrose Park IL 60160 800 729 0307 or 708 865 8870 Fax 708 865 2941 www peerlessmounts com ISSUED 06 05 06 SHEET 202 9142 4 12 06 06 ...

Page 2: ...d installation is not UL evaluated If mounting to wood wall studs make sure that mounting screws are anchored into the center of the studs Use of an edge to edge stud finder is highly recommended Always use an assistant or mechanical lifting equipment to safely lift and position equipment Tighten screws and nuts firmly but do not overtighten Overtightening can damage the items greatly reducing the...

Page 3: ...062 delrin washer 4 540 1070 540 1070 K 8 32 x 375 socket head cap screw 2 520 1210 520 1210 L plastic finishing cap 6 590 1123 590 1123 M holdingpin 2 580 1166 580 1166 N retainerplug 2 590 1007 590 1007 O 5 16 x 3 wood screw 8 520 1243 520 1243 P 250 x 1 x 068 washer 8 540 1063 540 1063 Q 9 64 allen wrench 1 560 9728 560 9728 R cable management clips 8 590 1166 590 1166 S cable tie 8 590 1168 59...

Page 4: ...dapter bracket 1 201 1110 201 4110 201 1110 201 4110 BB shallow adapter bracket 2 200 0756 200 0757 200 0754 200 0755 CC deep adapter bracket 2 200 0752 200 0753 200 0750 200 0751 DD allen wrench 1 560 9646 560 9646 560 0072 560 0072 Before you begin make sure all parts shown are included with your product Adapter Bracket Parts List DD CC BB AA ...

Page 5: ...acket Fasteners M6 x 20 mm 4 520 9554 M6 x 30 mm 4 520 1067 M8 x 15 mm 6 520 1068 M8 x 40 mm 4 520 1152 M8 x 25 mm 4 520 1101 M6 x 20 mm 4 520 9402 M6 x 30 mm 4 510 9109 multi washer 6 580 1036 M8 x 16 mm 6 520 9257 M8 x 40 mm 4 520 1136 M4 x 12 mm 6 504 9013 Phillips Adapter Bracket Fasteners M4 x 25 mm 4 504 1015 M5 x 12 mm 4 520 1027 M5 x 25 mm 4 520 9543 M6 x 12 mm 4 520 1128 M6 x 25 mm 4 520 ...

Page 6: ... through standard thickness drywall or plaster into wood studs Installers are responsible to provide hardware for other types of mounting situations Never exceed the Maximum UL Load Capacity of 200 lb 91 kg 1 WARNING Installation to Wood Stud Wall Wall plate A can be mounted to two studs that are 16 apart Use a stud finder to locate the edges of the studs Use of an edge to edge stud finder is high...

Page 7: ...lb 91 kg WARNING Always attach concrete expansion anchors directly to load bearing concrete Never attach concrete expansion anchors to concrete covered with plaster drywall or other finishing mate rial If mounting to concrete surfaces covered with a finishing surface is unavoidable the finishing surface must be counterbored as shown below If plaster drywall is thicker than 5 8 custom fasteners mus...

Page 8: ...sh sleeves to cables 3 CORD MANAGEMENT CHANNEL C 3 1 Note There are three mounting positions The center position is shown right Arm assemblies must be mounted with one mounting hole separating them Slide washers J over wall support arm axles D Next insert plastic caps N into axles Then insert holding pins M into axles See detail 1 Note Fit of axles D into wall plate A and arm assembly C will be ti...

Page 9: ...th four M10 socket screws F Tighten screws using 6 mm allen wrench U Do not overtighten screws Overtightening may hinder roll option CAUTION B I F A L E 5 E 4 Attach two pieces of vinyl trim E to wall plate A Next attach one piece of vinyl trim to bottom of swivel box on arm assembly C 4 1 Insert one finishing cap L into each unused hole of wall plate A SWIVEL BOX C AA ...

Page 10: ...ws F Insert carriage bolt I into slot of swivel box as shown in figure 6 1 Install nylon washer G and tilt adjustment knob H Install remaining two M10 screws F as shown in figure 6 2 HAND TIGHTEN all four M10 screws to allow for tilt adjustment Remove tape from carriage bolt I For tilt adjustment gently push back on the top of plasma to relieve pressure on knob Adjust tilt to desired position and ...

Page 11: ...n figure 7 1 Attach the adapter brackets to the back of the screen using the appropriate combination of screws multi wash ers and spacers as shown in figure 7 3 Note Top and bottom holes must always be used Verify that all holes are properly aligned and then tighten screws using a phillips screwdriver Note If using security screws tighten using security allen wrench DD If screws don t get three co...

Page 12: ...ast six times to prevent screen from being removed as shown in detail 4 Tighten using allen wrench DD Screen can be adjusted horizontally if desired Note To lock the screen down tighten screws to adapter bracket as shown in detail 4 To remove screen from mount loosen screws swing screen away from mount and lift screen off of mount 8 AA BB or CC DETAIL 4 SCREWS AA BB or CC Always use an assistant o...

Page 13: ...en or tighten screws more than 1 8 turn Depending on the specific size weight of the plasma articulating swing arm may be angled at different positions causing plasma to appear to lean sideways at different articulating positions Tilt roll assembly B allows plasma to be manually adjusted so plasma can be horizontal at all positions To adjust gently rotate plasma by hand to desired position 9 9 1 A...