ISSUED: 05-25-05  SHEET #: 055-9247-6 11-08-06

Visit the Peerless Web Site at www.peerlessmounts.com

4 of 7

For customer care call 1-800-729-0307 or 708-865-8870.

Drill two 1/4" (6 mm) dia. holes to a minimum depth of
2.5" (64 mm). Attach ceiling plate (

G

) using two

concrete anchors and #14 x 2.5" wood screws (

F

) as

shown in 

Illustration A 

and

 1

2

, and 

(below).

Tighten all fasteners.

IMPORTANT: It is the responsibility of the installer
to verify that the ceiling will safely support the
combined load of all attached hardware and
components.

1

3

CUT

A

W

A

Y

 VIEW

INCORRECT

concrete

metal

bracket

plaster/

dry wall

CORRECT

concrete

metal

bracket

plaster/

dry wall

concrete
ceiling

concrete
anchor

concrete
anchor

concrete
anchor

F

F

Illustration A

Installation to Concrete Ceilings

ACC 203 (Alligator

® 

concrete anchors) are recommended.

2

G

FOR DIRECT ATTACHMENT TO LOAD BEARING
CONCRETE ONLY! 

Concrete expansion anchors are

not 

intended for attachment to concrete ceilings

covered with a layer of plaster, drywall, or other
finishing material. If mounting to concrete ceiling
covered with plaster / drywall is unavoidable, plaster /
drywall must be counterbored as shown below.

WARNING

F

G

CONCRETE CEILING

concrete
anchor

Drill hole and insert anchor

Place ceiling plate over anchor and secure with screw

After repeating step one tighten all fasteners

• Tighten wood screws so that wall plate is firmly

attached, but do not overtighten. Overtightening can
damage the screws, greatly reducing their holding
power.

• Never tighten in excess of 80 in • lb (9 N.M.).
• Make sure that mounting screws are anchored into the

center of the studs. The use of an "edge to edge" stud
finder is highly recommended.

WARNING

• When installing Peerless wall mounts on concrete, verify that you have a minimum of 1 5/8" of actual concrete surface

in the 1/4" diameter hole to be used for the concrete anchors. Do not drill into mortar joints! Concrete must meet
ASTM C-90 specifications.

• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard-

ware and components.

• Never exceed the Maximum UL Load Capacity of 50 lb (27 kg).

WARNING

Summary of Contents for Vector Pro II PJF2-UNV Series

Page 1: ...en you let go Applications FlushMount page 5 ExtensionColumn page 6 Installations To Wood Joist Finished Ceilings Exposed Wood Joists or Wood Beam Ceilings page 3 To Concrete Ceilings page 4 IMPORTANT Turn to the appropriate page for your ceiling installation Installation and Assembly Vector Pro II Models PJF2 UNV PJF2 UNV S PJF2 SERIES Refer to Model No Guide Sheet Makesurethatthesupportingsurfac...

Page 2: ...646 560 9646 C M5 x 8 x 10 mm socket pin type F screw 1 520 1164 520 2031 D 10 32 x 3 8 spade thumb screw 1 560 1107 560 2107 E 10 32 x 3 8 serrated washer head socket pin screw 1 520 1151 520 2151 F 14 x 2 5 phillips hex head wood screw 2 5S1 015 C03 5S1 015 C04 G ceiling plate 1 580 1042 580 4042 H 25 ID x 56 OD x 26 spacer 2 590 1050 590 2071 I extension column connector with cord management 1 ...

Page 3: ...ers H between ceiling plate G and ceiling Installation To Wood Joist Finished Ceilings Exposed Wood Joists or Wood Beam Ceilings WOOD JOIST CEILING F F G H H Tighten wood screws F so that wall plate G is firmly attached but do not overtighten Overtightening can damage the screws greatly reducing their holding power Never tighten in excess of 80 in lb 9 N M Make sure that mounting screws are anchor...

Page 4: ... material If mounting to concrete ceiling covered with plaster drywall is unavoidable plaster drywall must be counterbored as shown below WARNING F G CONCRETECEILING concrete anchor Drill hole and insert anchor Place ceiling plate over anchor and secure with screw After repeating step one tighten all fasteners Tighten wood screws so that wall plate is firmly attached but do not overtighten Overtig...

Page 5: ...ate G and secure ball and socket mount A with a M5 x 10 mm socket pin screw C using security allen wrench B as shown in detail 1 Note Slotted set screw K is used to jam against the threads of the ball and socket mount to prevent any excess movement of the ball and socket mount A Do not overtighten screw overtightening screw will damage threads making it difficult to separate the products Skip to s...

Page 6: ...sion column using security allen wrench B See detail 5 Screw ball and socket mount A to extension column connector I Align slot in ball and socket mount A to one of the bottom holes in extension column connector I Insert and tighten one 10 32 x 3 8 socket pin screw J through extension column connector into slot in ball and socket mount A using security allen wrench B See detail 6 Note Slotted set ...

Page 7: ...g the ball and socket mount A into the adapter plate connection and twisting until the adapter plate will no longer turn about 75 The spring loaded captive screw should line up with a corresponding hole on the adapter plate this should line up automatically when the two are connected Push down and tighten the spring loaded captive screw to secure the adapter plate to the mount If not using the opt...

Reviews: