ISSUED: 05-25-05 SHEET #: 055-9247-6 11-08-06
Visit the Peerless Web Site at www.peerlessmounts.com
5 of 7
For customer care call 1-800-729-0307 or 708-865-8870.
Screw ball and socket mount (
A
) into ceiling plate (
G
). Align the notch with one of the four holes of the ceiling plate
(
G
) and secure ball and socket mount (
A
) with a M5 x 10 mm socket pin screw (
C
) using security allen wrench (
B
)
as shown in
detail 1
.
Note:
Slotted set screw (
K
) is used to jam against the threads of the ball and socket mount to prevent any excess
movement of the ball and socket mount (
A
). Do not overtighten screw; overtightening screw will damage threads
making it difficult to separate the products.
Skip to step 3.
Flush Mount Application
DETAIL 1
A
G
A
C
WOOD
CEILING
NOTCH
G
K