background image

 

 

 
 

Peerless Pump Company 

 P.O. Box 7026 – Indianapolis, IN 46207-7026 
Phone: (317) 925-9661 – Fax: (317) 924-7388 
 
 
 
 
 
 
 

 

Item 

 

Description 

 * 1 
 * 2 
 * 3 
   4 
   5 
   6  
 * 7 
 * 8 
 * 9 
 *10 
 *11 
  12 
  13  
  14 
  15     
  16 
  17 
  18 
  19 
  20 
  21 
  22 
  23 
 *24 
 *25 
 *26 

Cover 
Slotted Screw 
Upper Gasket 
3/4" Pipe Plug 
3/4" Tee 
3/4" Nipple 
Ground Terminal 
Compression Fitting 
Phillips Head Screw 
Lower Gasket 
O-Ring 
Reducer 
Coupling Compression 
Set Screw Sq. Hd. 
Mounting Flange 
Gasket Mtg. Flg. 
Electrode Hsg. 
Suspension Wires 
Electrodes 
Bulb Adapter 
Hose Clamp 
Band Protector 
Bulb 
Housing 
Body 
Vent Cap 

 
(27)* These parts make up the Terminal Housing 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

4848247  

Rev. 2/2/05 

Summary of Contents for Sealtrode P Series

Page 1: ...y does not cover parts repaired outside the Seller s factory without prior written approval Seller makes no warranty as to starting equipment electrical apparatus or other material not of its manufacture since the same are usually covered by warranties of the respective manufacturers thereof Manufacturer and may also result in bodily injury as well as property damage This book is intended to be a ...

Page 2: ...use a good pipe thread compound to insure a watertight connection To protect and facilitate installation roll the flexible bulb into a compact bundle about its vertical axis and 4848247 2 Before attempting examination handling or repair be certain that the electrical power supply is shut off An electrical shock from contact with live wires or cards can be fatal Before opening the conduit box of an...

Page 3: ...4 AWG wire with 600 volts rated insulation and 3 64 inch minimum insulation wall thickness to connect the letter coded wires to the indicated terminals in the control box Be sure electric current is the same as that stamped on the control box nameplate Wire per wiring diagram supplied with control panel If diagram is lost or misplaced copies may be obtained from your local Peerless Pump representa...

Page 4: ...filled and the pumps do not cut off remove and empty the bulb and refill as outlined on page 3 under the heading Filling Flexible Bulb LOCATING TROUBLE IF THE PUMP FAILS TO START 1 Make sure sodium bicarbonate has been added to water 2 Check the electrical service making sure the current characteristics are the same as that stamped on the control box nameplate 3 Check to see if the control wiring ...

Page 5: ...DT 4848247 5 ...

Page 6: ...unted in enclosure for 1 phase motors only All mounted and pre wired in NEMA 1 general purpose or NEMA 4 watertight dead front enclosure 4848247 6 TYPE L and TYPE VCS PUMPS Fusible Disconnect Switch DY60FD Circuit Breaker DY60CB SERIES P DUPLEX COMBINATION SEALTRODE FLOATLESS CONTROLLER consists of A Electrode and terminal housing assembly including galvanized steel electrode housing NEMA 1 thru 4...

Page 7: ...or High Water Alarm Contacts Alarm Annunciation by others High Water Alarm with Annunciation Silencing Relay and Push Button Red High Water Alarm Light Enclosure Mounted Y 56 A U Y 56 A Simplex 2 X Y 57 A UH Y 57 A H Simplex 3 X X Y 57 AU A Y 57 A A Simplex 3 X Y 57 AU D Y 57 A D Duplex 3 X X Y 57 AU DH Y 57A DH Duplex 4 X X Y 57 AU DA Y 57 A DA Duplex 4 X Y 58 AU Y 58 A Duplex 3 X X Y 58 AU H Y 5...

Page 8: ...over Slotted Screw Upper Gasket 3 4 Pipe Plug 3 4 Tee 3 4 Nipple Ground Terminal Compression Fitting Phillips Head Screw Lower Gasket O Ring Reducer Coupling Compression Set Screw Sq Hd Mounting Flange Gasket Mtg Flg Electrode Hsg Suspension Wires Electrodes Bulb Adapter Hose Clamp Band Protector Bulb Housing Body Vent Cap 27 These parts make up the Terminal Housing 4848247 Rev 2 2 05 ...