ISSUED 08-09-06 SHEET #: 055-9470-1
Visit the Peerless Web Site at www.peerlessmounts.com
6 of 11
For customer care call 1-800-729-0307 or 708-865-8870.
Drill two 1/4" (6 mm) dia. holes to a minimum depth of
2.5" (64 mm). Attach projector mount assembly (
A
)
using two concrete anchors , two flat washers (
I
), and
two #14 x 2.5" wood screws as shown in
Illustration
A
and
1
,
2
, and
3
(below). Tighten wood screws (
V
)
using 3/8" (10 mm) socket wrench until projector
mount assembly (
A
) is firmly attached.
1
3
Drill hole and insert anchor
Place ceiling plate or mount over anchor and secure
with screw
After repeating step one tighten all fasteners
CUT
A
W
A
Y
VIEW
INCORRECT
concrete
metal
bracket
plaster/
dry wall
CORRECT
concrete
metal
bracket
plaster/
dry wall
FOR DIRECT ATTACHMENT TO LOAD BEARING CONCRETE
ONLY!
Concrete expansion anchors are
not
intended for
attachment to concrete ceilings covered with a layer of plaster,
drywall, or other finishing material. If mounting to concrete
ceiling covered with plaster / drywall is unavoidable, plaster /
drywall must be counterbored as shown below.
concrete
ceiling
Illustration A
Installation to Concrete Ceilings
A
2
A
CONCRETE CEILING
I
Note:
It is the responsibility of the installer to
verify that the ceiling will safely support the
combined load of all attached hardware and
components.
Skip to step 4.
FRONT OF
MOUNT
• Do not tighten screws with excessive force.
Overtightening can damage screws, greatly reducing
their holding power. Tighten to 80 in • lb (9 N.M.)
maximum torque.
CAUTION
3
V
W
W
W
V
W