19
XIV. ROUT INE M A INTENA NCE
Care of Nameplate
The large nameplate on the front side of the WEATHER
PICTURE should be cleaned with a soft damp cloth only. Use no
harsh or abrasive cleaners, as these will permanently scratch the
surface of the nameplate. Do not spray any liquids or cleaners
directly on the nameplate.
In Case of Non-Responsive WEA T HER PICTURE
Sometimes an electrical storm or line power surge can cause the
weather station keyboard or WEATHER PICTURE to be disabled.
To correct this condition, unplug the WEATHER PICTURES
power cord from its AC adapter, and re-plug to power up again.
If this does not correct the problem, unplug the junction box cable
from the back of the weather station keyboard display and
remove the 9-volt battery (however, be advised that all memories
and initial settings will be lost). Install the battery again and
reconnect the junction box cable.
Error Codes
On occasion an error code may appear in a Numeric Display:
Code
Meaning
Corrective Action
Err1 Invalid DIP Switch Setting Correct DIP switch setting; see
Section IV "Selecting Numeric
Display Functions".
Err2 No Serial Input
Check wiring diagram, cable
connections from Weather
Station keyboard, or Display
Module wire harness
connectors.
Err3 Keyboard in Packet Mode Change Serial Port to Complete
Record or Data Logger Mode.
Err4 Keyboard not in Complete Change Serial Port to Complete
Record Mode
Record Mode.
Err5 Sensor Not Found
Correct DIP switch setting or
add required weather sensor.
Err8 Unexpected Interrupt
Call Technical Support.