AI Trouble shooting
Symptom
Cause
Remedy
11
11
10
6
7
11
Always turn off the power, unplug the machine and then well-qualified technicians should troubleshoot a problem.
If trouble occurs frequently, stop using the device and contact your local dealer or Pegasus' sales office.
In the case of the adjustment that is made with the power on, well-qualified technicians should carry out this adjustment
with great care because the machine could start unexpectedly.
CAUTION
CAUTION
Reference
page
The Al device is not
turned on.
While the power of the
machine is on, the motor
for the Al device keeps
on running.
The power relay cord is not
connected correctly to the
controller.
Faulty wiring inside the power
switch (push button)
The fuse for the controller has
a break.
Connect the power relay cord correctly.
At this time check to make sure the
power relay cord to be used matches
the supply voltage.
Connect the wires of the same colors.
Replace the fuse.
Three sensors on the Al motor
are out of where these sensors
can detect the lever.
Position the lever as shown below.
In the case of the
maximum reverse
differential feed
In the case of the
maximum differential
feed
When the power or the machine
is off, the differential lever is out
of any one of three sensors.
Even if the power or the machine
is off, the differential lever should
be aligned with any one of three
sensors.
The relay cords for three sensors
on the Al motor are disconnected.
Connect the relay cords of the
same colors correctly.