Page 34 Rev. 02-21
USER MANUAL
VAR.
MEANING
VALUES
DEFAULT
ES-3M
ES-6
MS
Setting the Master-Slave operating mode.
(with MS=0 Modbus is enabled)
0 = Single
4 = 3 slaves
1 = Slave
5 = 4 slaves
2 = 1 slave
6 = 5 slaves
3 = 2 slaves
0 ÷ 6
0
0
Bdr
Modbus baudrate
< Range: 0÷ 8 >
0 = 300 baud 3 = 2400 baud 6 = 14400 baud
1 = 600 baud 4 = 4800 baud 7 = 19200 baud
2 = 1200 baud 5 = 9600 baud 8 = 38400 baud
0 ÷ 8
5
5
Prt
Configuration of the Modbus parity check.
< Range: 0 ÷ 2 >
0 = No parity
1 = Even parity
2 = Odd parity
0 ÷ 2
0
0
P1
Password: type of protection
(active when PA is different from 0)
< Range: 0 ÷ 2 >
0 = it only displays the set point and allows to silence the alarms
1 = blocks access in 1st and 2nd level programming (all other
functions are allowed)
2 = blocks access in 2nd level programming (all other functions
are allowed).
0 ÷ 2
2
2
PA
Password
(see P1 for the type of protection)
< Range: 0 ÷ 999 / 0 = Disabled >
0 ÷ 999
0
0
rEL
MASTER software release
read only
19
19