1.  General

1.1  Application

The weekly shutter timer (291 JR) is used in combina-

tion with relay inset 293/2. The weekly shutter timer can 

be used to automatically or manually control a shutter, 

blind or awning. It can be switched using two relay inset 

remote stations.

– Manual operation

– Adjustable intervals

– Day/Week programming

– 24 programmable switch times

– 30  minutes  reserve  power  in  case  of  power  failure, 

  no loss of programming.

Note: 

Read through the operating instructions carefully 

before putting the device into service. 

1.2  Warranty conditions 

These operating instructions are an integral part of both 

the  device  and  our  terms  of  warranty.  They  must  be 

handed  over  to  the  user. The  technical  design  of  the 

device  is  subject  to  change  without  prior  notification. 

PEHA 

products are manufactured and quality-checked 

using the latest technology and according to applicable 

national and international regulations. Nevertheless, if a 

product should exhibit a defect, 

PEHA 

warrants to make 

remedy as follows (regardless of any claims against the 

dealer to which the end-user may be entitled as a result 

of the sales transaction): 

In the event of a justified and properly-established claim, 

PEHA

 shall exercise its prerogative to either repair or 

replace the defective device. Further claims or liability 

for consequential damage are explicitly excluded. A jus-

tifiable deficiency is one in which the device exhibits a 

structural, manufacturing, or material defect that makes 

it unusable or substantially impairs its utility at the time 

it  is  turned  over  to  the  end-user.  The  warranty  does 

not apply to natural wear, unintended usage, incorrect 

connection, device tampering or the effects of external 

influences. The warranty period is for 24 months from 

the date of purchase by the end-user from a dealer and 

ends not later than 36 months after the device’s date 

of manufacture. German law shall be applicable for the 

settlement of warranty claims.

1.3  Disposal of the device 

The device must be disposed of in compliance with the 

laws  and  standards  of  the  country  in  which  it  is  ope-

rated!

2.  Safety

This  device  is  only  intended  to  be  used  for  its  stated 

application. Unauthorised conversions, modifications or 

changes  are  not  permissible!  This  device  may  not  be 

used in conjunction with other devices whose operation 

could present a hazard to persons, animals or property.

The following must be observed:

•  The operating instructions for the device and the relay 

  insets.

•  Operating instructions can only cite general stipula-  

  tions. These are to be viewed in the context of a spe- 

  cific system.

3.  Technical specifications

4.  Structure and description

4.1  View and accessories

4.2  Display and operating buttons

5.  Installation and commissioning

5.1  Important installation information!!

– Only connect the shutter timer to the relay inset 293/2.

– Only  remove  or  plug  the  shutter  timer  into  the  jack 

  when the power is turned off.

– Only use one motor for each shutter timer!

– Only use indoors.

5.2  Installation

•  Assemble  and  install  the  relay  inset  in  accordance 

  with the instructions (should only be performed by a 

  qualified electrician).

•  Carefully plug the shutter timer into the jack.

5.3  Start-up

•  Switch on the power supply following installation.

•  Programme the basic setting (see 6.1).

•  Programme the shutter timers (see 6.2).

6.  Functions

6.1  Basic settings

The basic setting must be programmed prior to first use 

or following a reset.

Step 1: 

Set time and day

Notes:

– The setting for time and day of the week is 

  activated automatically if no time is stored.

– The device returns automatically to basic display if no  

  buttons are pressed for 30s.

Step 2: 

Set the interval

Shutters, blinds and aw-

nings are not always the 

same length. As such the 

interval  (time  between 

CLOSE and OPEN) must 

be set.

CLOSE position 

 

a

 Close completely

OPEN position 

   

a

 Open completely

Factory interval settings:

CLOSE position  

a

 close completely   t = 30s 

OPEN position     

a

 open completely   t = 30s

Notes:

- The OPEN position (open completely) must be set be- 

  fore setting the interval!

- The device returns automatically to basic display if no  

  buttons are pressed for 30s.

Art. no. 

291 JR 

Installation height 

0,8 – 1,5 m 

Minimum transit time 

1 minute 

Ambient temperature 

0° to + 40

q

C

Storage temperature 

- 25° to + 75°C 

Identification

CE

Type of protection 

IP20

1

16:40

day

prg

 

 

293/2

 230V~/µ4A 50Hz 

 L

Weekly shutter timer (291 JR)

Relay inset  293/2

Jack for up-

per section

        Up
        Down

        Select part of week / day

        Activate programming mode

        Set time and day

        Reset 

Note: 

The 

day 

and 

prg

  buttons  are  only  used  when 

the shutter timer is commissioned for the first time or 

programmed.

p

p

day

prg

"LUVFMMFS8PDIFOUBH

.FOV

.POUBH

1SPHSBNNJFSVOH

.FOV

;FJUFJOTUFMMVOH

3JDIUVOHTBO[FJHF

4QFJDIFSQMBU[

.BOVFMMF#FEJFOVOH

       

Menu

programming

Menu

time setting

Manual operation

Memory capacity

Display directon

Current weekday

1 = Monday

1

17:40

prg

Programming mode

(Display flashes)

press for about 3s

07:20

Prog.

01

1    2    3    4    5    6    7

Complete setting

Press

Activate interval 

setting

press simulta-

neously

day

prg

t030

p

Set CLOSE position

press until

CLOSE position

 

p

Set OPEN position

press until

OPEN position 

p

t020

p

t025

p

Time flashes

press for about 3s 

1

00:00

1

00:00

1

15:45

Set the time

press briefly:

Set the minutes

press longer:

Set the hours

p

p

1  2  

3  

4  5  6  7

15:45

Set the day of the week

press day

1 = Mon, 2 = Tues, 3 = Wed,

4 = Thur, 5 = Fri ...........

day

Complete setting

Press

Summary of Contents for 293/2 o.A.

Page 1: ...t oder u erer Einwirkung Die An spruchsfrist betr gt 24 Monate ab Kauf des Ger tes durch den Endverbraucher bei einem H ndler und endet sp testens 36 Monate nach Herstellung des Ge r tes F r die Abwi...

Page 2: ...ltuhren wird z B mit rE 21 21 restliche Schaltuhren angezeigt Ohne die Bet tigung einer Taste kehrt das Ger t nach 30s automatisch zur Grundanzeige zur ck c Schaltuhr l schen 22 00 Prog 02 1 2 3 4 5 2...

Page 3: ...for the device and the relay insets Operating instructions can only cite general stipula tions These are to be viewed in the context of a spe cific system 3 Technical specifications 4 Structure and de...

Page 4: ...lectrician only 8 2 Contact Telephone 49 0 2351 185 0 Fax 49 0 2351 27666 Internet www peha de contact aspx E Mail peha peha de Day of the week Mon 1 Tues 2 Wed 3 Thur 4 Fri 5 Sat 6 Sun 7 Part of week...

Page 5: ...emene aanwijzingen aandragen Deze moeten in samen hang met een specifieke installatie worden gezien 3 Technische gegevens 4 Opbouw en beschrijving 4 1 Aanzicht en toebehoren 4 2 Aanduidingen en bedien...

Page 6: ...1 2 3 4 5 21 30 Prog 02 1 2 3 4 5 Weekblok of weekdag instellen Kort indrukken day Schakeltijd instellen Kort indrukken Minuten instellen Lang indrukken Uren instellen p p t030 p p t025 p Indrukken p...

Page 7: ...ires 4 2 cran d affichage et touches de commande 5 Installation et mise en service 5 1 Consignes d installation importantes N utiliser la minuterie pour volets roulants qu avec l insert relais 293 2 N...

Page 8: ...E Mail peha peha de Jour de la semaine Lun 1 Mar 2 Mer 3 Jeu 4 Vend 5 Sam 6 Dim 7 Bloc de la semaine Lun dim semaine enti re a 1 2 3 4 5 6 7 Lun sam longue semaine de travail a 1 2 3 4 5 6 Lun ven se...

Reviews: