291 JR (Rev01_080725)
31060000-145
Installation and operating instructions
Upper section weekly shutter timer
for FM relay inset 293/2 o.A.
Art. No.:
291 JR
GB
1. General
1.1 Application
The weekly shutter timer (291 JR) is used in combina-
tion with relay inset 293/2. The weekly shutter timer can
be used to automatically or manually control a shutter,
blind or awning. It can be switched using two relay inset
remote stations.
– Manual operation
– Adjustable intervals
– Day/Week programming
– 24 programmable switch times
– 30 minutes reserve power in case of power failure,
no loss of programming.
Note:
Read through the operating instructions carefully
before putting the device into service.
1.2 Warranty conditions
These operating instructions are an integral part of both
the device and our terms of warranty. They must be
handed over to the user. The technical design of the
device is subject to change without prior notification.
PEHA
products are manufactured and quality-checked
using the latest technology and according to applicable
national and international regulations. Nevertheless, if a
product should exhibit a defect,
PEHA
warrants to make
remedy as follows (regardless of any claims against the
dealer to which the end-user may be entitled as a result
of the sales transaction):
In the event of a justified and properly-established claim,
PEHA
shall exercise its prerogative to either repair or
replace the defective device. Further claims or liability
for consequential damage are explicitly excluded. A jus-
tifiable deficiency is one in which the device exhibits a
structural, manufacturing, or material defect that makes
it unusable or substantially impairs its utility at the time
it is turned over to the end-user. The warranty does
not apply to natural wear, unintended usage, incorrect
connection, device tampering or the effects of external
influences. The warranty period is for 24 months from
the date of purchase by the end-user from a dealer and
ends not later than 36 months after the device’s date
of manufacture. German law shall be applicable for the
settlement of warranty claims.
1.3 Disposal of the device
The device must be disposed of in compliance with the
laws and standards of the country in which it is ope-
rated!
2. Safety
This device is only intended to be used for its stated
application. Unauthorised conversions, modifications or
changes are not permissible! This device may not be
used in conjunction with other devices whose operation
could present a hazard to persons, animals or property.
The following must be observed:
• The operating instructions for the device and the relay
insets.
• Operating instructions can only cite general stipula-
tions. These are to be viewed in the context of a spe-
cific system.
3. Technical specifications
4. Structure and description
4.1 View and accessories
4.2 Display and operating buttons
5. Installation and commissioning
5.1 Important installation information!!
– Only connect the shutter timer to the relay inset 293/2.
– Only remove or plug the shutter timer into the jack
when the power is turned off.
– Only use one motor for each shutter timer!
– Only use indoors.
5.2 Installation
• Assemble and install the relay inset in accordance
with the instructions (should only be performed by a
qualified electrician).
• Carefully plug the shutter timer into the jack.
5.3 Start-up
• Switch on the power supply following installation.
• Programme the basic setting (see 6.1).
• Programme the shutter timers (see 6.2).
6. Functions
6.1 Basic settings
The basic setting must be programmed prior to first use
or following a reset.
Step 1:
Set time and day
Notes:
– The setting for time and day of the week is
activated automatically if no time is stored.
– The device returns automatically to basic display if no
buttons are pressed for 30s.
Step 2:
Set the interval
Shutters, blinds and aw-
nings are not always the
same length. As such the
interval (time between
CLOSE and OPEN) must
be set.
CLOSE position
a
Close completely
OPEN position
a
Open completely
Factory interval settings:
CLOSE position
a
close completely t = 30s
OPEN position
a
open completely t = 30s
Notes:
- The OPEN position (open completely) must be set be-
fore setting the interval!
- The device returns automatically to basic display if no
buttons are pressed for 30s.
Art. no.
291 JR
Installation height
0,8 – 1,5 m
Minimum transit time
1 minute
Ambient temperature
0° to + 40
q
C
Storage temperature
- 25° to + 75°C
Identification
CE
Type of protection
IP20
1
16:40
�
�
day
prg
293/2
230V~/µ4A 50Hz
L
�
�
Weekly shutter timer (291 JR)
Relay inset 293/2
Jack for up-
per section
Up
Down
Select part of week / day
Activate programming mode
Set time and day
Reset
Note:
The
day
and
prg
buttons are only used when
the shutter timer is commissioned for the first time or
programmed.
p
p
day
prg
"LUVFMMFS8PDIFOUBH
.FOV
.POUBH
1SPHSBNNJFSVOH
.FOV
;FJUFJOTUFMMVOH
3JDIUVOHTBO[FJHF
4QFJDIFSQMBU[
.BOVFMMF#FEJFOVOH
Menu
programming
Menu
time setting
Manual operation
Memory capacity
Display directon
Current weekday
1 = Monday
1
17:40
prg
Programming mode
(Display flashes)
press for about 3s
07:20
Prog.
01
1 2 3 4 5 6 7
Complete setting
Press
Activate interval
setting
press simulta-
neously
day
prg
t030
p
Set CLOSE position
press until
CLOSE position
p
Set OPEN position
press until
OPEN position
p
t020
p
t025
p
Time flashes
press for about 3s
1
00:00
1
00:00
1
15:45
Set the time
press briefly:
Set the minutes
press longer:
Set the hours
p
p
1 2
3
4 5 6 7
15:45
Set the day of the week
press day
1 = Mon, 2 = Tues, 3 = Wed,
4 = Thur, 5 = Fri ...........
day
Complete setting
Press