5.1 Note on installation
• Do not use in the open (only within closed rooms).
• Before the installation on rough surfaces, a smooth surface has to be created.
Unevenness may lead to transmitter’s malfunctions.
• When installing, mind the required position of installation shown on the back of
the transmitter (O = top ,
I
= bottom)
(1)
.
• Do NEVER install the transmitter within a metal body or in the immediate vicinity
of big metal objects. An installation near or on the ground is not recommendable.
5.2 Mounting
a) Screws:
• Retaining plates
(4)
shall be used as a template to mark the drill holes.
• Drill dowel holes of 5 mm.
•
Fix the retaining plate with included screws. The latches of the retainin plate
have to be positioned for their installation as shown under
point 4
.
• Engage wall transmitter
(2)
and frame
(3)
on the retaining plate.
b) Gluing:
• Engage wall transmitter
(2)
and frame
(3)
on the retaining plate
(4)
.
• Use
adhesive strips
for the installation on flat, smooth surfaces (such as
painted walls, tiles, furniture, wood, etc.) Glue the adhesive strip to both
the upper and lower recess on the indentation of the retaining plate.
•
Use
adhesive film
for the installation on glass. Glue the adhesive film to the
inverse side of the retaining plate.
•
Glue the assembled wall transmitter to the desired place.
5.3 Commissioning
• Installation of the receiver (only by an electrician).
• Assign wall transmitter to receiver.
6.1 New system or existing system
• Check the immediate surroundings of the systems for changes that might cause
malfunctions (for example, previously moved metal cabinets, furniture or walls).
• If transmitter/receiver work at a closer distance, there either might be interference
or the system was used outside the transmission range.
• Placement of the transmitter at a more convenient location.
6.2 Radio signal range limitations
• Use of the transmitter/receiver in the vicinity of metal objects or materials with
metal components. Maintain a distance of at least 10 cm.
• Moist materials.
• Devices which emit high-frequency signals (e.g. audio and video systems, compu-
ters, electronic ballasts in lightfixtures). Maintain a distance of at least 0.5 m.
6.3 Contact
Telephone:................ +49 (0)2351 185-0
Fax:.......................... +49 (0)2351 27666
Internet:.................... www.peha.de/contact.aspx
E-mail:...................... peha@peha.de
PEHA products may be sold and operated in EU countries as well as in CH, IS
and N. PEHA herewith declares that the Easyclick wall transmitter is in compli-
ance with the fundamental requirements and other relevant provisions of R&TTE
Directive 1999/5/EC. The conformity declaration is available on the Internet at the
following address: www.peha.de/ServiceDownloads.aspx.
1
2
3
4
5. Mounting and commissioning
6. Troubleshooting & remedies
7.
Conformity declaration